WMI Counters | UVexplorer Manual

PRTG Manual: WMI Counters

The WMI monitor allows you to query custom attributes from the device using WMI and compare them to expected results.

Configuring the Monitor

The WMI monitor editor contains the following tabs that require configuration: Settings, Devices, Schedule, Event, and History.

The Schedule, Events and History settings are the same for all monitor types. See Configuring Monitors for more information about configuring these settings. For the settings tab see the information below.

Settings

Name

The Monitor name is the name used to refer to the monitor in the monitors list view, and in monitor events and notifications. Monitor names need not be unique, but it is recommended that you use unique names to differentiate them.

WMI Queries

The WMI Queries section is a list of the WMI queries that the monitor will perform.

Adding a WMI Query

To add a WMI Query press the add button uvx_image_10. An editor allowing you to configure the query is displayed. Once configured press the save button and the query is added to the list.

Editing a WMI Query

To edit a WMI Query double click the Query in the list or press the edit/configure button uvx_image_13. The configuration editor is displayed. To save the changes press the save button and the changes are applied.

Deleting a WMI Query

To delete a WMI Query select the query in the list and press the delete button uvx_image_12. The query will be removed from the list.

Configuring a WMI Query

A WMI Query contains the following settings.

WQL/Query

The WQL query to perform against the device. WQL is SQL for WMI and allows you to query information from Microsoft Windows devices on which WMI access is enabled. You can either enter your own WQL query, or click on the button next to the WQL / Query field (with the binoculars icon) to select from a list of pre-made queries. (See Microsoft’s MSDN documentation for more information about WQL.)

The WQL query that you enter should return a single value that the monitor can check for validity (as opposed to a query that returns multiple values).

Name

Name is a description of the WQL query.

Use Expected Value

If you select Use Expected Value, the monitor will compare the WMI response with the value you specify in the Expected Value field. By default, the monitor will check that the WMI response value equals the expected value. However, if you check the Verify Not Equal box, the monitor will check that the WMI response value does not equal the expected value.

Use Thresholds

Use Thresholds can be used with numeric WQL responses to ensure that the value of the response does not exceed the specified Warning and Critical levels. If the value exceeds the Warning level, the monitor will report the Warning state. If the value exceeds the Critical level, the monitor will report the Down state. (The Critical value should be greater than or equal to the Warning value.)

If you check the Alert When Less Than box, the monitor will work in the opposite direction. That is, it will ensure that the value of the response does not go lower than the specified Warning and Critical levels. If the value goes below the Warning level, the monitor will report the Warning state. If the value goes below the Critical level, the monitor will report the Down state. (In this case, the Critical value should be less than or equal to the Warning value.)

Devices

The devices tab allows you to select which devices will be monitored. To add devices to the monitor select the uvx_image_10 button in the lower left corner. A device selector will be presented allowing you to choose one or more devices to monitor. To remove a device from the monitor select it in the grid and press the delete button uvx_image_12.