We improved the tooltip text information for the setting Parameters in the sensor Settings for EXE/Script and EXE/Script Advanced sensor types. If you hover over the tooltip icon for Parameters, you can see the following additional information: This setting can pose a security risk because sensitive information in the parameters appear in the sensor log. Use placeholders like %windowspassword or %scriptplaceholder1 to encrypt sensitive information and enable PowerShell Security Enhancement under Setup Monitoring Experimental Features to increase your security. This information is valid for the Result of Sensor [Sensor ID].Data.txt that is created when you have enabled the Result Handling option Store result in the sensor Settings.
You are now able to include the HTTP v2 sensor in a device template when you have added the sensor to an appropriately configured device before. The device template is created when the HTTP endpoint returns status 200 (OK), using the same settings as the templated sensor. You can edit the device template afterwards if you need different status codes.
Various other minor fixes and improvements, updated user manual.
We fixed an issue that led to probes being disconnected from time to time when they were connected via communication protocol with very high latency.
We fixed an issue where changes via PRTG API v2 to any API key were not saved in the History tab of a user account. For example, when you created or modified an API key using /api/v2/users/api-keys/ endpoint, the changes would not be logged in your user account History tab.
We fixed an issue for the WMI Event Log sensor where the entry for Log file in the WMI Event Log Monitor settings was missing when you ran an auto-discovery with device template before that included this sensor type.
We fixed an issue where the System Information page was not displayed for some devices in the PRTG App for Desktop. Also for API calls https://
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.3.100.1279
You are now able to include the REST Custom v2 (BETA) sensor in a device template when you have added the sensor to an appropriately configured device before. When you run an auto-discovery with the mentioned device template on a new device, the sensor will be created afterwards. Please note that you need to enable the PRTG BETA feature under Experimental Features in the PRTG Setup first in order to use this sensor.
You are now able to include the SSH INodes Free v2 sensor in a device template when you have added the sensor to an appropriately configured device before. When you run an auto-discovery with the mentioned device template on a new device, the sensor will be created afterwards. Please note that you need to enable the PRTG BETA feature under Experimental Features in the PRTG Setup first in order to use this sensor.
With this PRTG version we announce the deprecation of several endpoints in the PRTG API v2. Deprecation for endpoints means, that they will be removed or replaced in the future, therefore please make sure to check if you are using some of them and prepare to migrate to the replacement endpoints. For example, the endpoint GET /channels will be replaced by /channels/{id} and /experiemental/channels, whereas the experimental endpoint can still be changed but is aimed to become a stable endpoint as well. In course of this change, we also removed the following experimental endpoints: GET /experimental/devices/id/settings, GET /experimental/sensors/id/settings. In the section /overview for the OpenAPI Documentation, we added detailed information about filtering, include parameters and endpoint maturity. For all relevant documentation, please have a look at Important changes to API v2 in PRTG 24.3.100
We fixed an issue where the generic autogenerated Examples for any API call did not work anymore and the returned response for those examples was not correct. For example, when you opened the call for GET Channels with the Example Channels you would not get all available fields or correct naming in the Example Value. To open the Swagger UI you need to enter http(s)://<(yourprtgserver)>:Port/api/v2/oas/.
We fixed an issue that occurred when you selected the Color Mode Dark in the PRTG classic interface and opened the new UI afterwards. Previously, not all settings and pages, for example reports and sensor settings, were displayed in Dark mode but still shown as Light (default).
We fixed an issue where linked objects in maps opened in PRTG classic interface. The issue occurred when you used the Select object option in the maps Properties, for example, to create a link. The link will then direct to the PRTG classic interface instead of the new UI.
We fixed an issue where the context menu was available for objects included in iframe pages in the new UI. For example, if you right-clicked on a parent object in settings like the Inherit from location, a context menu opened what should not have been available in this case.
You are now able to view and edit settings in the PRTG Setup pages within the new UI when you are logged in with an account with administrative rights. This includes all setup pages under System Administration, however, the License Information page will direct you to the classic UI currently when you want to update information on your license in the new UI.
To ensure secure communication furthermore we updated to OpenSSL version 3.0.13 since OpenSSL also retired the 1.1.1 series end of September 2023. The following TLS versions will be supported in the connection security settings for Probe Connection and PRTG Web Server settings: TLS 1.3, TLS 1.2, TLS 1.1, TLS 1.0.
Please note when you update to this PRTG version, that you cannot add new installations of mini probes because OpenSSL 1.0.2 is no longer supported. Existing installations of mini probes should not be affected.
We updated the API call that is used within the Cisco Meraki Network Health sensor since the formerly used API call /organizations/{organizationId}/devices/statuses was deprecated.
We improved the stability on PRTG probe level to avoid the risk of probe issues, such as access violations in the probe.log or a no longer working probe service.
With this PRTG version we introduce the new Virtual Domain Settings (VDOM) where you can select the virtual domain that this sensor monitors during sensor creation. Existing sensors are unaffected as the setting will show the default value root.
You will now see an additional section under Optional Downloads in the PRTG setup menu for the Multi-Platform Probe. This section can be found in the menu point Remote Probes and contains a link to the Multi-Platform Probe manual with installation guide, a download link for the required NATS server Download NATS Server for PRTG installer and additionally a step-by-step instruction for the Paessler Linux package repository (Debian and Ubuntu and RHEL). You can install the RPM package on a Linux system running Red Hat Enterprise Linux (RHEL) version 9.
We removed the notification on the PRTG Status page under Probes for connected Multi-Platform Probes that you need to install .NET for the Multi-Platform Probe.
Various other minor fixes and improvements, updated user manual.
We updated the Japanese language files.
We changed the Teams Webhook feature for notifications Send Microsoft Teams Message in PRTG, since Microsoft will retire Office 365 connectors within Microsoft Teams. Microsoft provides the new Workflows app that you can use for a workflow to post messages from a webhook request. With this PRTG version, Send Microsoft Teams Message notifications will now support Workflows webhooks that you can configure in your Microsoft Teams. For more information on how to set up your Teams notification in PRTG please see our Knowledge Base article: How do I create a webhook for the PRTG notifications to Slack and Microsoft Teams?
We fixed an issue where the DNS v2 sensor with Query Type Host address IPv6 (AAAA) or Host address IPv4 (A) (default) only considered one IP address returned by a hostname instead of any matching IP address. For example, if you wanted to check entries of a same DNS for IPv4 and IPv6 addresses in separate devices and an entry for IPv6 was missing or invalid, both variants (IPv4 and IPv6) would fail what instead should have been only the sensor running on the IPv6 device.
We fixed an issue for the MQTT Round Trip sensor where the default value was not displayed correctly in the MQTT Specific settings for Topic. Previously, the sensor Topic displayed was PRTG/roundtrip/%%sensorid.
We fixed an issue where the SNMP Uptime v2 sensor was not displayed in the map properties Top 10 lists for Longest System Uptime and Shortest System Uptime in previous PRTG versions. You could observe that other SNMP Uptime and WMI Uptime sensors on your system were shown in the lists but the SNMP Uptime v2 was missing.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.3.99.1463
You are now able to include the Cisco WLC Access Point Overview (BETA) sensor in a device template when you have added the sensor to an appropriately configured device before. When you run an auto-discovery with the mentioned device template on a new device, the sensor will be created afterwards. Please note that you need to enable the PRTG BETA feature under Experimental Features in the PRTG Setup first in order to use this sensor.
You can try out the experimental SSH INodes Free v2 (BETA) sensor that monitors the free index nodes on disks of Linux/Unix and macOS systems via Secure Shell (SSH) and which was rewritten to work also on the Multi-Platform Probe. This sensor comes with the channels Downtime and Free INodes [Mount], like the former SSH INodes Free sensor. Please note that this sensor does not support the Compatibility mode for SSH Engine anymore. This feature was already deprecated in previous PRTG versions.
You are now able to include the SNMP Custom v2 (BETA) sensor in a device template when you have added the sensor to an appropriately configured device before. When you run an auto-discovery with the mentioned device template on a new device, the sensor will be created afterwards. Please note that you need to enable the PRTG BETA feature under Experimental Features in the PRTG Setup first in order to use this sensor.
You can now create a group in the new UI via context menu and action button on probe and group level with the corresponding user rights. After you have created a group, you will be redirected to the parent object where the group was created. Please note that you cannot add a group on root level.
We adjusted the wording for Edit Settings in the context menu when you opened it for a sensor. The menu option Edit Settings was displayed twice, however, the wording with the wheel icon should have been Edit Channel Settings instead of Edit Settings.
We added an automatic login timeout that happens after inactivity for 15 minutes when you are logged in on PRTG and want to navigate to the System Setup pages. You will then be logged out and receive a message Please re-enter your credentials to gain access to admin settings. After you have entered your login credentials again, you will be redirected to the page you wanted to navigate to before the automatic login timeout.
We fixed an issue that occurred in the Firefox browser console when you navigated to or within the Monitoring option. The JavaScript error message displayed was uncaught (in promise).
We fixed an issue for lookup bars in the new UI mobile view that were not displayed in the correct color mode like they are shown in the desktop view.
We added tabs for Logs and Maps to the main menu below the home icon where you are now able to create, edit and view maps within the new UI and where you can also view your logs for objects. When you open the Logs tab, you can see an additional filter option Choose Filter where you can select, for example, Filter: paused/resumed for objects. Please note that the feature for map rotation is currently disabled in the new UI.
We improved the setup page in the new UI for users without administrative rights. You will now have the sections Account Settings, Optional Downloads and Support on the Settings (setup) page in PRTG. Under Account Settings you now have the option to manage your API Keys and My Account settings. Please note that a user with read only rights is not allowed to access the setup main page and will instead receive a 403 - access denied error.
We fixed an issue that occurred when you navigated from the Sunburst view to the Tree view and vice versa with your keyboard arrows and clicked enter to confirm. Previously, you would see an unknown error displayed with the message An unknown error occurred. If necessary, try to reload the page.
We updated the German, Spanish, French, Portuguese, Russian, Japanese, Chinese and Dutch language files.
We fixed an issue for the PRTG application server that occurred in the previous Preview version 24.3.98.1197 where you could observe an excessive increase in memory consumption in the Application Server Health (Autonomous) sensor. The issue occurred in connection to the newly introduced endpoints for sensor channel settings.
Please note that a certain rise in memory is noticeable and expected due to this new endpoint but should not exceed more than 70kb per channel.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.3.98.1205
With this PRTG version we provide various fixes to improve security and stability.
We improved the error message for certain sensor types that appears when you need to check credentials or logfiles for a sensor. Affected sensors are AWS sensors, EXE/Script sensors, Zoom sensor, Veeam sensors, OPC UA sensors and Cloud sensors. The previous error message did not indicate that the setting for Store Result is not enabled by default and that you first need to enable it and run a rescan of the sensor before you can check the logfiles. An example error message now displays The sensor could not authenticate with AWS. Check your credentials for AWS or select 'Store result' under Debug Options | Result Handling in the sensor settings, rescan, and check the \\Logs\\sensors subfolder of the PRTG data directory on the probe system.
Various other minor fixes and improvements, updated user manual.
We updated the information for Possible Values in the section Sorting and Advanced Filtering in our user manual.
We fixed an issue for API keys that did not display the correct Access Level when the user to whom the API key was assigned was deleted or moved from the corresponding user group. The API Key List has now an additional column Effective Access Level that displays the up to date and in use access level for the relevant user.
We fixed an issue where a Core logfile was created on a remote probe after you started the Administration Tool on that relevant remote probe. The logfile was created under C:\ProgramData\Paessler\PRTG Network Monitor\Logs\core.
We fixed an issue for the HPE 3PAR Drive Enclosure sensor that led to several issues when you used multiple sensors of that type on the same device on the same probe. The sensors would report an error with the message that the session could not be started (Cryptographic functions must be set on at least one blocksize). In some cases the sensors would work again if you enabled the Store Result function, but then ran into an unknown state if you disabled it again.
Important:This fix introduces a maximum number of parallel connections to the same device with same credentials. If that limit is reached then you will receive the error too many concurrent connections. This limit is currently hard-coded to 20 concurrent connections with the same credentials/device combination within the HPE 3PAR Drive Enclosure sensor. This issue also occurred on the Multi-Platform Probe.
Your Microsoft Azure and Microsoft 365 sensors will now use correctly proxy settings when you have configured those on the relevant device. Previously, the proxy settings were displayed correctly in the logs but disregarded for Azure AD login.
We fixed an issue for the OPC UA Custom sensor that reported an error with the message No Value is set in certain cases. The issue could happen in cases when the DisplayName, BrowseName or Description attribute was empty.
We fixed an issue for the WMI Event Log sensor where the sensor did no longer display a sensor event message for triggered events. You could observe the missing information in the Message column of the Log tab of the sensor as well as in the sensor status bar below the sensor name. The sensor also only reported the status OK in certain cases.
You will notice a higher memory usage on your system when you run the PRTG application server and when you update to this PRTG preview version 24.3.98.1197. The issue occurs because a change for channel settings in the PRTG API v2 requires more memory. We are working on a fix for this issue with high priority.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.3.98.1197
We improved the text message that is displayed when you are logged out due to inactivity. Previously, the message displayed was Your have been logged out due to inactivity.
You are now able to edit the settings of a sensor channel via the PRTG new UI. On a channel card of a sensor you will now see an additional Actions button: Edit Settings. This button will open a new dialogue window where you can make changes to the selected channel. If you do not change anything or if you enter invalid values, the Save Settings button will stay inactive.
The Script v2 sensor left its BETA status with this PRTG version and is now fully supported. We introduced this sensor type as experimental sensor with PRTG version 23.1.82.2074. The sensor executes a Python script that returns data in JSON format and shows the exit code. This way you can create your own custom script sensors that may not be available in PRTG by default. For available example scripts and how to use them, please see the Knowledge Base article: I want to use the Script v2 sensor example scripts. What do I need to know?
You are now able to delete created API keys under Account Settings in your PRTG Setup via multi-edit selection. Previously, API keys could only be deleted individually. For every API key that you delete, PRTG will add an entry in the History tab of your User Account settings.
You can now add multiple subnets to the auto discovery setting. If you want to include multiple addresses and subnets, enter them in the field IPv4 and Subnet (IPv4) as a list separated by a comma. Please note that this feature applies only for IPv4 subnets and does not support IPv6.
We updated the available lookup values for NetApp v2 sensors that were not supported in previous PRTG versions before. For example, the NetApp System Health v2 sensor now supports the values Tri Path, Tri Path HA and Virtual state for the status Up in the Storage Configuration Path channel. Other NetApp v2 sensors that have now addtional supported lookup values are NetApp SnapMirror v2 for the channels Mirror State and Policy Type and NetApp NIC v2 sensor for the channel State.
With this PRTG version we introduce a new setting Microsoft Azure Management Endpoint in the Credentials for Microsoft Azure. This setting allows you to change the API endpoint for your region that can differ from the default URL management.azure.com to use Microsoft Azure sensors, such as Microsoft Azure SQL Database sensor or Microsoft Azure Storage Account sensor in your environment. Please note that this setting is locked by default and can be edited upon request.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files for certain selected sensor types.
We updated the versions supported for Veeam sensors (Veeam Backup Job Status sensor, Veeam Backup Job Status Advanced sensor) regarding the Veeam Backup Enterprise Manager.
We removed the following libraries from the Sensor System since they are no longer needed: MongoDB.Bson.dll, MongoDB.Driver.dll, Mono.Security.dll. The libraries were a leftover from the MongoDB System Health sensor that we announced as deprecated with PRTG version 16.2.23 and finally removed from PRTG with PRTG version 16.3.25.
We fixed an issue where the PRTG Core server generated a high CPU usage when you used an API call for a historic data report with a negative average interval avg=-[interval]. PRTG considered the API call as invalid in these cases and could not respond what caused a timeout and thus lead to a higher usage in CPU.
We fixed an issue that occurred when you updated to the previous PRTG version 24.2.94 where in certain cases the PRTG core server service could not start and could not be restarted as well. The PRTG web interface would report timeouts or load endlessly after login. In some other rare cases, the update to PRTG version 24.2.94 was successful, however, the web interface performance was very slow in loading pages and you also could observe ReadLock entries in the core.log. Rolling back to the former PRTG version 24.1.92.1554 would solve the issue.
We fixed an issue where the installer window for a remote probe could not be closed with the x button in certain cases. The issue happened when you changed the Setup in your PRTG installation under Probe Connection Settings to allow probe connections to the core server when you already executed the remote probe installer. The installation process could be finished successfully, however, you were not able to close the dialogue window of the remote probe installer.
We fixed an issue for the AWS EC2 v2 sensor that reported the error message Channel with ID [ID ]is not defined in very rare cases because the sensor sometimes received zero 0 values for the DiskReadOps (Average) metrics. Since the sensor expects values for every scan, it reported the mentioned error when it received 0 values. The issue occurred when you used the sensor on a Linux instance but could also occur on a AWS EC2 Windows system.
Running an auto-discovery with a device template that includes the following sensor types will now add these sensor types to your device as expected: Windows Print Queue sensor, VMware Datastore (SOAP) sensor and SMTP&IMAP Round Trip sensor.
We fixed an issue for Microsoft Azure sensors, like Microsoft Azure Storage Account sensor, Microsoft Azure SQL Database sensor or Microsoft Azure Subscription Cost sensor, where the Result of Sensor log reported the error The sensor could not get a response from the server. 400 (Bad Request) in certain cases. The issue occurred when you used a scanning interval of 12h or 24h because the sensor used an invalid format that could not be handled by the Azure REST API.
You can now create a device template from a device that includes a POP3 sensor and the sensor will be added to the device afterwards. In previous PRTG versions, when you opened the dialogue window Create Device Template, the sensor was not added to the relevant device after you received the success message Create Template Results, although the sensor was listed in the results.
We reduced the possibility of a higher memory consumption and a memory leak on the probe that occurred in certain cases when you ran SNMP and HTTP/HTTP Advanced sensors on your local or remote probe. Eventually, the probe would report the status disconnected. Restarting services only helped for a certain while in these cases.
We reduced the risk for PRTG logs to get a large file size when WMI exceptions occur, especially for the ProbeWMI.log. This could lead to a full disk in certain cases since the file size increased very quickly and therefor result in a not working probe system in the worst case.
We adapted the information for Result Handling in the Debug Options help tooltip so that it displays the correct file name and subfolder where the sensor result is stored. The file name now is UDP Debug Port [Port][Date].log in the Logs/debug subfolder for both sensor types.
We fixed an issue where the PRTG MultiBoard ran into a timeout in the previous PRTG version 24.2.96.1315 when you used the Template Transfer (BETA) feature in order to move a custom device template from one PRTG server to another. Please note that this feature is only available when you run PRTG with a Paessler PRTG Enterprise license.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.2.97.1683
You can try out the experimental Cisco WLC Access Point Overview sensor (BETA) that monitors your access points that are connected to your Cisco Wireless LAN Controller (WLC). The sensor will show the following columns during sensor creation: MAC address, Name, Location, State for the access points as well as IP address, Model, Serial Number and Number of Slots. The Number of Slots represents the number of radios and antennas for an access point. The sensor comes with the channels Operational Status, Admin Status, Max Rx Utilization, Max Tx Utilization, Max Channel Utilization, Client Count and Client Count with Poor SNR (Signal to Noise ratio).