You can now define a scale factor as integer or floating-point number for the MQTT Subscribe Custom sensor in the sensor settings during sensor creation. The setting is available in the MQTT Specific settings and can be defined in the Scale Factor setting of a channel when the Channel Unit is set to custom. The default scale value is set to 1 and can be changed depending on whether you want to scale up or down. You can change this setting later after sensor creation in the Edit Channel settings under Scaling Multiplication.
Various other minor fixes and improvements, updated user manual.
The PRTG application server will now be installed by default when you install PRTG for the first time with a valid license key. This change applies only for new installations that do not have a trial key license, existing PRTG version updates are not affected. After you have set up a fresh installation of PRTG, you will see the Open new UI button on the login page. Additionally, the PRTG application server service is available and running on your system.
For more information, please see our Knowledge Base article: I want to use the new UI and API v2. What do I need to know?
We fixed an issue that occurred in the CoreActivation logfile when you used a trial license key for a PRTG offline activation. The activation was successful, however, the CoreActivation log would show an error unknown license selector passed. The issue was due to our internal license processing and did not have any functional impact.
We fixed an issue for the MQTT Round Trip sensor that was not added to a device when you used this sensor in a device template and the Port configured was not default 1883. For example, when you changed the default Port of a device in the Credentials for MQTT to secure connection Port 8883 and ran Run Auto-Discovery with Template with MQTT Round Trip selected, no sensors would be created afterwards.
You can now generate a Historic Data report when you click on the arrow button behind the Start button that is displayed in the Historic Data tab for Historic Data Report Settings. In previous PRTG versions, the report could not be created and instead an error message was displayed: PRTG Network Monitor has encountered a problem. Your last request could not be processed properly.
With this PRTG version we announce the deprecation of the Python Script Advanced sensor as of PRTG version 25.x.106. You will receive a corresponding PRTG to do ticket when you update to this PRTG version and when you have added the Python Script Advanced sensor to your PRTG installation.
The Python Script Advanced sensor will be deprecated and cannot be added anew as of PRTG 25.x.106. Please use the successor sensor Script v2 instead. For more information please see our Knowledge Base article: What do deprecation and discontinuation in the context of sensors mean?
Read here for differences and more information about the two sensors: Why should I use the Script v2 sensor?
We also provide information on how to migrate your scripts with this Knowledge Base article: How can I make my Python scripts work with the Script v2 sensor?
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.4.103.1665
Preview 24.4.103.1638
We fixed an issue for the Cisco WLC Access Point Overview sensor that reported the error message The returned result from OID...is the wrong type ('Error'). The expected type is 'Integer (32bit)' in certain cases what resulted in access points not being able to be monitored. The issue occurred in cases when the Number of Slots during sensor creation reported more slots then were actually successful for an access point. For example, the SNMP response during sensor scan reported 2 slots, slot 0 did work whereas slot 1 failed. The sensor will now no longer report an error in these cases but show the data of the successful slots instead. Additionally, you can change the number of slots in the Cisco WLC Access Point Overview Specific settings upon request with the lock button.
We fixed an issue for creating objects when the parent (e.g. device, group) was deleted in the meantime. In previous PRTG versions, you would receive an unspecific error message in this case. The error message now displays that the object could not be created: The parent object does not exist. It might have been deleted.
You can now set a different Refresh Interval (Sec.) for a page refresh in PRTG in your Account Settings for PRTG Web Interface. In previous PRTG versions, you were able to save your settings, however, the refresh timer in the page footer was not updated.
We improved the message toast that is displayed when you save settings on pages throughout PRTG in the new UI. The message that is displayed after you have saved your settings successfully will now show Settings have been saved. For Map comments and Report comment setting changes, the message displayed will be Comments have been saved.
We improved the message for new added sensors to a device when there is no data available yet. Previously, when you navigated to the sensor overview page of a new created sensor when no data was available yet, you would see the message No matches could be found. The message now displayed in such cases is No data yet.
The new UI and APIv2 now support the login via Single Sign-on with this PRTG release. When you want to use the PRTG application server, you do not need to specify any new callback URLs on your PRTG instance under Available Callback URLs in the Single Sign-on Settings. However, you need to configure the callback URL within the single sign-on provider for any domain that the appserver is reachable under (Okta or Entra ID). For more information on how to set up SSO, please see our Knowledge Base article: How to integrate Microsoft Entra ID into PRTG? and How to integrate Okta SSO into PRTG?
You are now able to see and access the tabs Log and History in the new UI provided that you have the according user rights for the relevant object. Please note that there is no contex menu available for object links, for example in the Log tab when you right click on a sensor or device.
We updated our API for maptiles and geocoding since the API from the location service provider has changed. In previous PRTG versions you would notice that there was no resolution anymore in some cases for your given geo location in the Location (for Geo Maps) and no map was displayed. This could have affected also new set geo locations while the old API was not working anymore.
Important: Please note that in certain rare cases you will need to take further action to make your geo location map work again. For example, when you have added a location by address in the Location (for Geo Maps) while the old API was not working, you will need to enter a (space, character) again in the location field and the map is displayed correctly when you update to this PRTG version. However, if you have entered the address as coordinates in the map before, no further action is required.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.4.102.1344
PRTG now supports the Single Sign-on (SSO) capability through its auto-login function. This allows you to gain access to multiple systems that support Single Sign-on with a single login in the same browser. For example, if you have a PRTG instance configured with Single Sign-on Entra provider and you log in to the portal of your provider by using SSO, no further login (two factor authentication) is required when you want to log in to your PRTG. Upon logout, you will be redirected to the login page.
Important: In certain cases you will not see a login page for Single Sign-on although you have configured and enabled it correctly in PRTG to use the new auto-login function. More precisely, this means if you want to log in with a different user account without using Single Sign-on or if the callback URI is wrong or invalid in the portal of the SSO provider (Entra or Okta). You will receive an error message, for example A silent sign-in request was sent but no user is signed in or The redirect URI (URI) specified in the request does not match the redirect URIs configured for the application (applicationID).
If that happens, please use /public/local_login.htm for a regular login procedure. Another option would be to disable Single Sign-on in PRTG or to update the callback URIs in the portal of your SSO provider.
You can now define a scale factor as integer or floating-point number for the Modbus TCP Custom sensor and Modbus RTU Custom sensor in the sensor settings during sensor creation. The setting is available in the Modbus Channel Specific settings and can be defined in the Scale Factor setting of a channel when the Channel Unit is set to custom. The default scale value is set to 1 and can be changed depending on whether you want to scale up or down. You can change this setting later after sensor creation in the Edit Channel settings under Scaling Multiplication.
Various other minor fixes and improvements, updated user manual.
We fixed an issue for Graph Settings in the User Interface section of the PRTG Setup menu that were no longer applied. For example, if you changed the setting of a graph to another value then the default (like for Graph 3 365 days to 400 days), PRTG would not apply the changes after an automatic restart but still display the previous default in the group, device or sensor graphs.
We fixed an issue for the SSL Security Check sensor that reported the status Denied in the channel TLS. 1.0 (Weak) or TLS 1.1 (Weak) although those TLS protocols were still accepted by the webserver. This issue happened in some cases when you updated to the previous PRTG version 24.3.100.1361.
You are now able to navigate through the pages when you have many entries in a map or when you use data tables in a map. In previous PRTG versions, the pagination in maps did not work.
We fixed an issue where sensor result messages where ignored by PRTG Core server in certain cases when too many messages were sent to the core at once. This could lead to gaps in monitoring data, especially when the PRTG core server was reconnecting or restarting.
We face an issue with the HPE ProLiant Physical Disk sensor that you can no longer create and existing sensors may also no longer work in certain cases. When you try to create the sensor, the scan will fail with the message The sensor could not find any disks on the target device. For existing sensors you will notice the error No such instance (SNMP error # 223) and that the disk could not be found in these cases. The issue is located in the HPE Integrated Lights-Out (iLO 5) firmware version as of 3.x due to changes in the OIDs. A possible workaround is to downgrade to an older iLO version (before iLO 3.x).
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.4.102.1333
You can now define a scale factor as integer or floating-point number for the REST Custom v2 sensor in the sensor settings during sensor creation. The setting is available in the Channel Settings and can be defined in the Scale Factor setting of a channel when the Channel Unit is set to custom. The default scale value is set to 1 and can be changed depending on whether you want to scale up or down. You can change this setting later after sensor creation in the Edit Channel settings under Scaling Multiplication.
You will now be able to still navigate through and see the split view with the device tree in case there is a deleted object (group, device, sensor). The split view on the right hand side will display a broken image, for example: oops... the group could not be found. Addtionally, there is a redirect link Return to monitoring view. In case the user has no according rights for the relevant object, the page will display an access denied error message.
The SNMP Disk Free v2 sensor left its BETA status and is now fully supported. We introduced the SNMP Disk Free v2 as experimental sensor with PRTG version 23.3.86.1520. The SNMP Disk Free v2 sensor monitors the free disk space on a logical disk via the Simple Network Management Protocol (SNMP).
To monitor Microsoft SQL Server as of version 2022, we implemented the WMI Microsoft SQL Server 2022 sensor (NEW). The WMI Microsoft SQL Server 2022 sensor monitors the performance of a Microsoft SQL Server via Windows Management Instrumentation (WMI).
We hardened the PRTG web UI against possible Tabnabbing attacks. The CVSSv3.1 score for this vulnerability is 2.6 but specifically for PRTG the severity is calculated as Medium.
We added an enpoint to get information about an API key token with Token Type Desktop. The endpoint getdesktoptoken.htm with given authentication credentials will return a configured API key token for the type Desktop. In case there is none configured, the page will return a corresponding error message. In this case, you can also find the following log entry in the CoreWebserverLog: Webserver: Error: no Desktop-type token found.
Your SNMP HPE ProLiant Physical Disk sensor is now able to display an additional status value for the Disk Status channel. Previously, the status for Hot Spare disks was not included in the standard lookup prtg.standardlookups.hp.diskstatus and therefore the sensor reported an error with the message Undefined lookup value - (10) in channel Disk Status.
We improved the wording displayed in the Help text for certain sensor types like Script v2 sensor, HTTP v2 sensor and REST Custom v2 sensor in the sensor Settings. For example, in the Parameters tooltip help text for EXE/Script sensors in the sensor Settings, the examples were previously displayed as %%host or %%sensorid.
Various other minor fixes and improvements, updated user manual.
We deprecated the option Run the command as a different user using 'su' in the device settings for Credentials for Linux/Solaris/macOS (SSH/WBEM) Systems for password security reasons. You will receive a corresponding TO DO ticket in PRTG that your action is required when you update to this PRTG version. For the SSH Rights Elevation method, please switch to the option Run the command as a different user using 'sudo' (without password) instead for all affected devices.
We fixed an issue in the Oracle Tablespace sensor scanning time so that the sensor executes the queries faster without running into timeouts, especially when you monitor a larger Oracle database.
We fixed an issue for API keys where it was possible for a user with read-write permission to delete an API key (that has write, acknowledge or read permission) with an API token that only has Acknowledge permission. Now users can only change their own API keys as long as they have the according rights to change it, this means at least write access except for PRTG administrators when additionally the API key has the access level FULL. This fix also applies for the PRTG API v2.
We fixed an issue that was logged in the CoreWebServer.log when you tried to move objects in a device tree in PRTG. The log in the CoreWebServer.log registered the error Webserver: Internal Error C0...Can't upgrade to writelock - lock is not upgradeable.
We fixed an issue for the Notification template Add Entry to Event Log where PRTG did not add an entry to the PRTG Network Monitor log file under Applications and Services Logs in the Windows event viewer when you have selected the option PRTG Network Monitor for the Log File setting before in the template. However, the issue did not occur when the Log File setting was set to Application, where PRTG successfully added an entry to the Application log file in the event viewer.
We fixed an issue in the Map designer of PRTG where the Custom HTML property did not work anymore in previous PRTG versions. The changes were not applied when you entered an HTML code in the HTML Before field, for example, to use the Custom HTML element in a map.
We fixed an issue for the usage of tags in PRTG, where quotation marks used in tags were not considered. For example, if you add a tag "hello and world", PRTG would create a single tag instead of two individual ones. This issue occurred also for tags used between the tags with quotation marks where PRTG would integrate them in one single tag only.
We fixed an issue that occurred when you had only one map available in PRTG, for example, after PRTG installation if you have deleted other maps except for one. In these cases, the clone button for the existing map was missing in the menu.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.4.101.1624
We improved the sensor message that is displayed for the REST Custom v2 sensor to have a better readability. There was previously no separation with commas if, for example, more channels were displayed in the message as information.
For the SNMP Custom v2 sensor, we also deliver the following improvements with this PRTG release:
Important: Please note that you need to create this sensor type new when you update to this PRTG version, as existing SNMP Custom v2 sensors will stop working upon updating.
You can try out the experimental SNMP UPS Status sensor that monitors the status of an uninterruptible power supply (UPS) via SNMP. This sensor comes with the channels Battery Status, Charge Remaining, Current Load and Estimated Time Remaining. You need to enable the PRTG BETA feature under Experimental Features in the PRTG Setup first in order to use this sensor.
You can try out the experimental SSH Meminfo v2 sensor that monitors the memory usage of a Linux/Unix system using Secure Shell (SSH). This sensor comes with the channels Available Memory (bytes) and Percent Available Memory (%). Please note that this sensor does not support any macOs distributions. You need to enable the PRTG BETA feature under Experimental Features in the PRTG Setup first in order to use this sensor.
You can try out the experimental SSH Load Average v2 sensor that monitors the load average of a Linux/Unix system using Secure Shell (SSH). This sensor comes with the channels 1 Minute, 5 Minutes, and 15 Minutes that reflect the average system load within a certain scanning interval. You need to enable the PRTG BETA feature under Experimental Features in the PRTG Setup first in order to use this sensor.
You can try out the experimental SSH Remote Ping v2 sensor that remotely monitors the connectivity between a system running Linux/macOS X and another device, using Internet Control Message Protocol (ICMP) echo requests ("ping") and Secure Shell (SSH). This sensor type comes with the channels Avg. Response, Max Response, Min Response and Packet Loss. The response time is measured from the remote device. You need to enable the PRTG BETA feature under Experimental Features in the PRTG Setup first in order to use this sensor.
We improved the wording used in the New UI context menus for more clarity and visibility. The wording was improved on sensor, device, channel, group and probe actions. Please note that a user without the accordings rights, for example read-only, will not see the action buttons in the context menu.
You are now able to access the PRTG Tickets tab in the new UI if you have the necessary rights. In the Tickets section, you can now assign, edit, resolve, close, change priority of the relevant tickets.
We fixed an issue for adding multiple users with the option Add Multiple Users under PRTG System Administration. The issue occurred after a certain time when you not confirmed your changes with OK directly. The page would then report an error in the Users Added pop up window.
We updated the German and Spanish language files.
We fixed an issue where the messages for the Syslog Receiver sensor were not displayed in the Messages and Sensor Overview tab after updating to the previous PRTG Preview version 24.3.100.1279.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.3.100.1325