• Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
 
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
Paessler
                    - The Monitoring Experts
  • Products
    • Paessler PRTG
      Paessler PRTGMonitor your whole IT infrastructure
      • PRTG Network Monitor
      • PRTG Enterprise Monitor
      • PRTG Hosted Monitor
      • PRTG MSP Edition
      • PRTG OT Edition
      • PRTG extensionsExtensions for Paessler PRTGExtend your monitoring to a new level
    • Icon Features
      FeaturesExplore all monitoring features
      • Maps & dashboards
      • Alerts & notifications
      • Multiple user interfaces
      • Distributed monitoring
      • Customizable reporting
      • Network Topology
  • Solutions
    • By TeamFor your organization size
      • Small Business IT
      • Mid-Market IT
      • Enterprise IT
      • MSP Network Monitoring
    • Industries
      By IndustryFor your business sector
      • Industrial
      • Healthcare
      • Energy
      • Government
      • Education
      • Data Center
      • Finance
    • IT Topics
      By Use CaseFor every technical scenario
      • Network Monitoring
      • Server Monitoring
      • OT Monitoring
      • Distributed Monitoring
      • Network Topology Mapping
      • SNMP Monitoring
      • Bandwidth Monitoring
  • Pricing
  • Resources
    • Getting Started
      Getting StartedModules for self-paced learning
    • How-to Guides
      How-to GuidesGet the most out of PRTG
    • Videos & Webinars
      Videos & WebinarsLearn from Paessler experts
    • Case StudiesProven results across industries
    • PRTG ManualFull documentation
    • Knowledge Base
      Knowledge BaseShare community knowledge
    • PRTG Sensor Hub
      PRTG Sensor HubGet sensors, scripts & templates
    • Trainings
      PRTG TrainingLearn how to work with PRTG
  • Partners
    • Icon Handshake
      Become a PartnerFor resellers and channel partners
    • Icon MSP
      Become an MSPDeliver monitoring as a managed service
    • icon partner
      Partner PortalLog in to your partner account
    • Deal Registration
      Deal RegistrationRegister your sales opportunities
    • icon search
      Find a PartnerFind partners selling Paessler products
    • icon technology
      Technology AlliancesSee Paessler technology partnerships
    • Partner HubTools for Your Success
  • Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
  • Get a quote
  • Free trial
  1. Home>
  2. Paessler PRTG>
  3. Version history>
  4. Preview release notes

PRTG Release Notes:
Preview Channel

Early Access to New Features

  • Preview versions give you early access to the latest features and improvements before they reach the stable channel. These versions have been thoroughly tested in our labs, but may still contain limitations in certain monitoring configurations. We do not recommend using preview versions in production environments.
  • To update your PRTG installation with the latest preview version, use the Auto-Update feature: In the PRTG web interface, navigate to Setup | Auto Update.
  • Looking for the most reliable version for your live environment? Check out our Stable Release Notes.
Stable Channel

PRTG Preview Version 25.3.111.1263

Release date: September 8, 2025
New

New

SNMP Linux Disk Free v2Sensors

With this PRTG version we introduce the new SNMP Linux Disk Free v2 sensor which is the successor to the SNMP Linux Disk Free sensor. This sensor monitors the free space on disks of a Linux/Unix system via SNMP. The SNMP Linux Disk Free v2 sensor is also compatible with the Multi-Platform Probe.

Improved

Improved

HTTP ClientSecurity

We updated our HTTP Client Axios for Browser and node.js to version 1.11.0 which fixes a critical vulnerability regarding the used form-data version.

SensorsSecurity

We hardened PRTG by improving input sanitization.

Channel limitsSensors

We updated the sensor schema for certain sensor types that is used for setting channel limits. Affected sensor types are the Script v2, SSH Script v2 (BETA) and REST JSON Data sensor (BETA) sensor. The schema was updated to version 3, which ensures support for setting channel limits.

All parts of PRTGVarious

Various other minor fixes and improvements, updated user manual.

Fixed

Fixed

Activation TokenServer

The Activation Token that shows the identifier of your license is now also displayed for PRTG offline license activations. You will see the Activation Token below your System ID on the License Status page when you select Manual (offline activation) for your license.

License activationServer

We fixed an issue that could occur during PRTG getting online activation data for a license and if PRTG encounters an exception at the same time. For example, in case of an 500 server error, PRTG would stop completely during activation resulting in an unavailable web interface. PRTG will now catch the exception and list it in the CoreActivation.Log. Furthermore, the PRTG web interface will be available and will direct you to the landing page /activation.htm in these cases.

WebserverServer

We fixed an issue regarding Overload Protection, where PRTG would display the message Warning! Overload protection is active! Click here to learn more even in cases when no Overload Protection was active due to how the value addition is handled for failed login attempts. For more information about Overload Protection and why it is used in PRTG, please see our Knowledge Base article: What is overload protection?

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 25.3.111.1263

  • sha256_exe 1047ED7222A9E9D89C4F9308A6EE2A1FFDFD02120886765DE3CA7D8DE6E7C2B1
  • sha256_zip 45678F81E731DC482ACA2F1783542215922A08540B321488CF41179C951D1D8C
Lab

Lab

APIPRTG API v2
  • We fixed an issue where it was possible to move the ProbeDevice via endpoint /experimental/devices/{id}/move to another Group/Device/Probe. The issue occurred also for the actions clone and delete via APIv2. The ProbeDevice is fixed in PRTG and cannot be deleted, cloned or moved anymore via APIv2.
  • The IP address is now logged in the core logfiles, furthermore the Audit Log, in case of a failed login via ApiToken-Provider. The issue occurred in the PRTG application server where the IP address was not set in previous PRTG versions and thus could not be logged in those cases.
  • You are now able to create the following sensor types with the new endpoint /experimental/devices/{id}/sensor via POST request: AWS Cost sensor, Cloud Ping sensor. The new endpoint is listed under the Sensors section in Swagger UI and gives you information about supported sensors. All setting sections, including lookups, are supported for this sensor type.
  • We have added the field primary that is included in the response code when you execute a GET request on the endpoint /experimental/channels. When you filter for the primary field (true or false) you will receive a list of primary or non-primary channels accordingly.
  • We fixed an issue for the experimental endpoint /experimental/devices that returned the status PAUSED_UNTIL for paused objects by user when you executed a GET request. This status did not match our Schema and will now return PAUSED_BY_USER_UNTIL for objects that were paused by user until a certain date or time.
  • We added two experimental endpoints /experimental/usergroups/{id} and /experimental/usergroups to PRTG API v2 that return a list of created user groups or by ID when you set the include parameter first upon a GET request.
PRTG application serverPRTG API v2
  • We fixed an issue for the PRTG application server that ignored parsing errors of the appserver.config.yaml and started with a default configuration. The PRTG application server will no longer start in this case and exit immediately, leaving a panic logfile with a message that explains the issue. This happened, for example, if lines for accesskey and clientuuid existed in the appserver.config.yaml.
  • We fixed an issue for the PRTG application server that occurred when you updated to PRTG version 25.2.108.1358. The PRTG application server would crash sporadically in certain cases and create a panic logfile with the message: panic: runtime error: invalid memory address or nil pointer dereference.
DependenciesNew UI

We added the option to select a sensor as dependency in the settings Schedules, Dependencies and Maintenance Windows. For the setting Dependency Type you will now see the radio button option Select a sensor. When you click on this option, a sensor selection UI appears, where you can choose from available sensor types.

Device settingsNew UI

You are now able to set a Scanning Interval in the device settings via drop down menu. Additionally you have the option to set a sensor Status with the setting If a Sensor Scanning Fails.

Device templatesNew UI

We added a selector for device templates that you can now open in the new UI of PRTG. The Confirm button is disabled when you do not make changes to the selection. When you change the selection for device templates, you are not able to close the dialogue but have to click Confirm instead.

GraphsNew UI

We fixed an issue for sensor graphs that were not correctly displayed in the new UI. For example, when you opened the Graphs tab of a sensor and used the Expand option and added one or two more channels, you would see only one channel graph in this case.

MonitoringNew UI

We fixed an issue where the vertical scrollbar on the Sensor List tab under Monitoring only appeared at the bottom of the page when you scrolled down. The vertical scrollbar is now visible on the whole page for the Sensor List if scrolling is necessary.

PRTG Preview Version 25.3.110.1311

Release date: August 25, 2025
Fixed

Fixed

SSH Remote Ping v2Sensors

We fixed an issue that occurred in certain cases when you replaced your SSH Remote Ping v1 sensors with the successor SSH Remote Ping v2 sensors. We deprecated the SSH Remote Ping v1 sensor with PRTG version 25.2.108.1358. In this case, the SSH Remote Ping v2 accidentially would use the SSH host as device instead of the remote target, what resulted in wrong values. You could also observe that the sensor did not display any packet loss which worked with the v1 sensor before.

PRTG API v2Server

We fixed an issue that occurred with latest Preview 25.3.110.1297 and which could have led to broken integrations that use PRTG API v2 endpoints, like for example, PRTG MultiBoard.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 25.3.110.1311

  • sha256_exe 94A77343A02D4F667A25B08C614B652D8335CD750016B033176D1B30148091F3
  •  
  • sha256_zip C9ED8E63DCE112E3118F023092F2337DACD26A1CD43BB3D8084499323F68C57B

PRTG Preview Version 25.3.110.1297

Release date: August 15, 2025
New

New

REST Custom v2Sensors

The REST Custom v2 sensor has left its BETA status and is now fully supported with this PRTG release. We introduced the REST Custom v2 sensor as experimental sensor with PRTG version 21.2.68.1492. The REST Custom v2 sensor queries a JSON or XML REST API endpoint and maps the according result to sensor values.

During sensor creation, the REST Custom v2 sensor will now have a pre-filled value in the field Request URL for the section Specific Sensor Settings. The field displays https://%host/ to make it easier to identify the supported placeholder. The Request URL field was empty before in previous PRTG versions.

Improved

Improved

REST APISensors

We improved the session based authentication method for REST API based sensors to accept more success response codes in the range of 200-299. The Credentials for REST API only accepted the HTTP response code 200 OK for session-based authentication in previous PRTG versions.

All parts of PRTGVarious

Various other minor fixes and improvements, updated user manual.

LanguagesVarious

We updated the German, Spanish and Japanese language files.

Sensor LanguagesVarious

We updated the language files in German, French, Portuguese, Russian, Chinese, Japanese and Dutch for certain selected sensor types.

Fixed

Fixed

DependencyServer

We fixed an issue where a device and sensor with status paused by dependency could not be resumed. The issue occurred, for example, if a sensor was put into simulated error status and this sensor was not set as Master sensor for parent on the according device. In this case, you could not resume the sensor afterwards as it also went into the state paused by dependency. The sensor will now remain in the error status to be able to be resumed again.

ReportsServer

We fixed an issue for reports that could not process umlauts correctly when you ran a report that included data files within the setting File Format and Delivery. For example, sensors with channel names that include umlauts were not displayed correctly in the xml file after generating the report with those sensors included. The issue occurred with PRTG version 25.1.104.1961.

Notification deliveryServer

We fixed an issue for SMTP notification delivery when you have set your Notification Delivery settings to Use direct delivery with the built-in email server (default). This issue occurred with updating to PRTG version 25.2.106.1114 where email notifications were sent several times instead of only once and was happening only for the PRTG internal SMTP relay server.

REST Custom v2Sensors

We fixed an issue for the REST Custom v2 sensor that ignored Custom HTTP Headers settings for the type Accept header. For example, if you defined an Accept header in the Custom HTTP Headers of the REST Custom v2 sensor, the header value would be overwritten in the previous PRTG version. The header is now transmitted correctly and you can see the value in the response of the Result of Sensor logfile.

SSH sensorsSensors

We fixed an issue that occurred for certain SSH v2 sensors when you updated to PRTG version 25.2.106.1114. The issue happened only for v2 sensor types, that is why you have been able to observe it in these particular cases after the sensor migration for the SSH INodes Free v1 sensor. The sensor was not able to reconnect to the target device after a broken connection in some circumstances, which we improved now by changing the logic for reconnection.

Note

Note

Discontinuation of Python Script Advanced sensor with PRTG 25.x.110Sensors

With this PRTG version we discontinue the Python Script Advanced sensor. We announced the deprecation of this sensor type with PRTG version 25.1.104.1946. Running sensors of this type will stop working and report an error message about the disontinuation and the Python installation will be removed when you update to this PRTG version. To ensure further monitoring, please use the successor Script v2 sensor instead and make sure to adjust your custom scripts in advance.

For more information please see our Knowledge Base article: What do deprecation and discontinuation in the context of sensors mean?

Read here for differences and more information about the two sensors: Why should I use the Script v2 sensor?

We also provide information on how to migrate your scripts with this Knowledge Base article: How can I make my Python scripts work with the Script v2 sensor?

License informationServer

With this PRTG version we display an Activation Token on the License Information page. This token shows the identifier of your activated license. The Activation Token is displayed for Paessler PRTG Enterprise and Subscription licenses and valid also for offline license activations.

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 25.3.110.1297

  • sha256_exe AEFAD074EE78A69BD1A252670AD2289662CCCA8A789558B510727056173B347C
  •  
  • sha256_zip 1AE61C2B3CCB9BE728BE84EBBCCC45D4A77FBE07C4A6EC7ACBCEA7A33FEE905B
Lab

Lab

REST JSON Data sensorSensors

You can try out the experimental REST JSON Data sensor (BETA) that we introcude with this PRTG version. This sensor queries an HTTP endpoint which returns JSON data in a well defined format. The format is the same as for the Script v2 sensor. Depending also on the JSON response, the sensor will create the channels Status and HTTP Status fix, amongst others. This sensor is also compatible with the Multi-Platform Probe.

PRTG application serverPRTG API v2
  • We improved the supported number of ciphers used in the TSL configuration for Default security (TLS 1.3, TLS 1.2) (recommended) that you can edit in the PRTG Web Server settings for Connection Security. The setting for Weakened security will still support older TLS versions and all current cipher suites used in the PRTG application server.
  • We fixed an issue that occurred in previous PRTG Preview version 25.3.109.1353 where an HSTS( Strict-Transport-Security) header was not sent correctly by the application server. The PRTG application server will now no longer send an example HSTS header during installation. Please use appserver.config.yml for configuration of an own HSTS header.
  • We fixed an issue for the PRTG application server that got stuck in certain cases during shutdown process and where it has hung up during the step unsubscribing from core notifications. As a result, also core and web server processes were not able to shutdown. A possible workaround was to manually stop the process.
LicensesPRTG API v2

We fixed an issue that occurred in certain cases when you have added a PRTG Subscription license and when displaying PRTG in the new UI was not possible. PRTG Subscription license types were enabled in the PRTG core, however, in certain cases the PRTG application server did not recognize them as valid. When you clicked on Open new UI button on the login page, PRTG would show An unknown error occurred in these cases.

PRTG Preview Version 25.3.109.1353

Release date: July 15, 2025
New

New

SSH Disk Free v2Sensors

The SSH Disk Free v2 sensor has left its BETA state with this PRTG version and is now fully supported. This sensor monitors the available disk space of a Linux/Unix system using Secure Shell (SSH). We released this sensor type as experimental (BETA) sensor with PRTG version 25.1.104.1946.

SNMP Linux Block Device I/O sensorSensors

With this version we introduce the new SNMP Linux Block Device I/O sensor, which is the successor to the SNMP Linux Physical Disk sensor. This sensors monitors the input/output (I/O) on disks of a Linux/Unix system via SNMP.

Improved

Improved

Sensorlist.htmSensors

To offer more details and information on a sensor, we added the following columns to the sensorlist.htm: Premeta (if the sensor requires a pre-meta scan), MinInterval and Momo (if it is a rewritten sensor type or not).

All parts of PRTGVarious

Various other minor fixes and improvements, updated user manual.

Fixed

Fixed

Add sensorServer

We fixed an issue that occurred on addsensor4.htm where large metascan entries during sensor creation could lead to an ajax timeout (PE:PE1113) in certain cases due to our update to Delphi 12.2 which also processes this page. This issue occurred, for example, if you tried to add SNMP Traffic sensors to a device with a large number of interfaces.

License activationServer

We fixed an issue where license activation for PRTG did not work in certain cases when the license activation file contained certain unicode/UTF characters that could not be decrypted. For example, when the license name included such a special character like Á or a long hyphen, you could observe the following error in the CoreActivationLog: No mapping for the Unicode character exists in the target multi-byte code page. The License status would also return Activation message processing has failed. in these cases.

NotificationsServer
  • We fixed an issue for email notifications that were sent immediately after a sensor went from paused state into a resumed state and therefore got the status unknown first before collecting data. The issue occurred when you have set a State trigger to this sensor that applies when the sensor stays in an unknown status for a certain time period. PRTG will now recognize the transition from paused state (by user, by dependency, by schedule, by license and until) and will only trigger the notification when the configured trigger applies.
  • You will now receive test notifications properly for MQTT messages within a notification template when you click on the button send test notification. In previous PRTG versions, PRTG would send the test notification with the prefix TEST, what therefore changed the topic you have subscribed to and thus you did not receive the according test notification. We have now added the wording TEST to the body of the notification, so that the topic will not change in this case.
AlarmsWeb GUI

We fixed an issue for Sensors With Alarms where objects were not displayed in the column Probe Group Devices. This issue was also fixed for the new UI and occurred only when you used Firefox as web browser.

PRTG TicketsWeb GUI

We fixed an issue in the PRTG Tickets tab that occurred in the Select a Group, Device or Sensor from the list section when you clicked on Add Ticket. The elements from the device tree would be overlapping in the search field in previous PRTG versions.

NetApp SnapMirror v2Sensors

We fixed an issue for the NetApp SnapMirror v2 sensor that reported the value 0 for the channel Lag in certain cases. The issue occured only for the NetApp SnapMirror v2 sensors. In course of this, we changed the default name of NetApp SnapMirror v2 sensors to show the destination path instead of the source path in the sensor name to ensure that the NetApp SnapMirror v2 sensor uses the same instance name as its predecessor NetApp SnapMirror v1.

Ping v2Sensors

The Ping v2 sensor will now keep the dependency when you create a device template with an according Ping v2 sensor that is set as Master sensor for parent for the device. Previously, when you run an Auto-discovery with specific device templates before, the Ping v2 sensor would be created afterwards, however, it was not set as Master sensor like in the original device.

SNMP v3Sensors

We fixed an issue for SNMP sensors that reported a timeout -2003 error in certain cases when you updated to the previous PRTG version 25.2.106.1114. The issue occurred in cases when you had SNMP sensors configured with SNMP version v3.

WMI Event Log sensorSensors

We fixed an issue for the WMI Event Log sensor where the handling for overflow values did not work properly. For example, when the sensor received and displayed values and you restarted the PRTG probe service, you could observe a high peak in the values afterwards.

Note

Note

SSH sensor migrationKnown Issues

There currently is an issue that occurrs in certain rare cases after sensor migration of SSH sensors. The SSH Inodes Free v2 sensor, for example, ran into a timeout under certain circumstances when you updated to PRTG version 25.2.106.1114 in which we introduced the migration process for this sensor type. In the Result of Sensor log, that is created when you enable Store Result for this sensor, you could also observe a connection failure and timeout error. We are investigating the problem with the highest priority.

Tree Version UpdateUpdate Notes

The configuration file of this version is not downwards compatible with previous PRTG versions.

Common SaaS sensorSensors

With this PRTG version we deprecate the Common SaaS sensor. You cannot add this sensor anew when you update to this PRTG version, however, existing sensor types continue to run. This sensor will not have a successor v2 sensor. You will receive an according TO DO ticket from PRTG when you update to this version.

SSH INodes Free sensorSensors

With this PRTG version we discontinue the SSH INodes Free v1 sensor. We announced the deprecation of the SSH INodes Free v1 sensor with PRTG version 25.2.106.1114 where also existing SSH INodes Free sensors were migrated to their successor v2 sensors. Please note that existing SSH INodes Free v1 sensors will stop working when you update to this PRTG versions, however, this does not apply for migrated SSH INodes Free sensors. It is not possible to create an SSH INodes Free v1 sensor anymore. For more information about sensor deprecation and discontinuation, please see our Knowledge Base article: What do deprecation and discontinuation in the context of a sensor mean?

Sensor migrationSensors

With this PRTG version, the following sensor types are migrated to their successor v2 sensors: SSH Meminfo, SSH Load Average and SSH Remote Ping sensor. PRTG will sent an according TO DO ticket with all relevant information. We announced the deprecation of SSH Meminfo, SSH Load Average and SSH Remote Ping sensor with PRTG version 25.2.108.1358.

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 25.3.109.1353

  • sha256_exe 66F1A52A815141F3368E2579BF877F3DE78DF7B214BFE0137840C7600BEA085C
  •  
  • sha256_zip 0DA9A568E3F7EC193F02AA4E3D726F8537020B91EFA9B79AB2C36C8D902D4BAB
Lab

Lab

REST Custom v2Sensors

We fixed an issue for REST Custom v2 sensors that went into a down or warning state with the message Creation of rest_custom_v2_sensor failed: The setting "authentication_section.authentication_group.login_path" was not available when you updated to PRTG version 25.2.108.1358. A possible workaround for this issue was to pause and resume the sensors to make them run again.

APIPRTG API v2
  • We improved our internal naming conventions to be more consistent in the format. In course of this, we renamed the property _inheritanceSource to to _inheritancesource.
  • We implemented a new endpoint /experimental/devices/templates that returns a list of available device templates upon GET request.
  • You are now able to create a Ping sensor with the new endpoint /experimental/devices/{id}/sensor via POST request. The new endpoint is listed under the Sensors section in Swagger UI and gives you information about supported sensors: This endpoint does not yet support all sensor types. Currently only the following sensors are supported: * Ping. The body of the POST request contains the settings of a ping sensor as defined in the schema, for example, required fields and settings sections.
  • We fixed an issue where a remote probe returned the status CONNECTED in the PRTG API v2 under yourserver:1615/api/v2/probes/ID although it was not approved yet. You will now receive the correct status for the remote probe PENDING_APPROVAL in this case.
  • You can now send a GET request on the endpoints /experimental/objects or experimental/groups/{0} with the include parameter and value all. Previously, the inheritanceSource would return unknown_reference_object_type for the type field. You will now receive correctly REFERENCED_ROOT.
InterfaceNew UI

We updated our typography throughout the New UI to match the design system.

PRTG Preview Version 25.2.108.1279

Release date: June 11, 2025
New

New

SNMP CPU Usage v2 sensorSensors

With this PRTG version, the SNMP CPU Usage v2 sensor left its BETA status and is now fully supported. This sensor type monitors the system load via the Simple Network Management Protocol (SNMP). We introduced this sensor type as experimental sensor with Preview version 25.2.107.1567.

SNMP Linux Load Average v2Sensors

With this PRTG version we introduce the new SNMP Linux Load Average v2 sensor that is the successor sensor for SNMP Linux Load Average. This sensor type was rewritten to be compatible with the Multi-Platform Probe. The SNMP Linux Load Average sensor monitors the system load average of a Linux/Unix system via the Simple Network Management Protocol (SNMP).

SNMP Linux Meminfo v2Sensors

With this PRTG version we introduce the new SNMP Linux Meminfo v2 sensor that is the successor sensor for SNMP Linux Meminfo sensor. This sensor type was rewritten to be compatible with the Multi-Platform Probe.

Please note that the channel Available Memory (%) has been renamed to Free Phyiscal (%) and vice versa to better match its purpose, for example, Available Memory (%) should be the memory that is available for applications if the operating system was also reclaiming buffers/cache space, whereas Free Phyical (%) is the value which is not in use currently.

SNMP Memory v2Sensors

With this PRTG version, the SNMP Memory v2 sensor left its BETA status and is now fully supported. This sensor type monitors the memory usage of a system via the Simple Network Management Protocol (SNMP). We introduced this sensor type as experimental sensor with Preview version 25.2.107.1567.

Improved

Improved

License activationServer

We improved the behavior of PRTG when you have activated a PRTG Subscription or Paessler PRTG Enterprise Monitor license that has expired or is going to expire. You will now receive a growl message that displays when your PRTG Subscription license has expired or will expire. In case of license expiration, the License Status will show the activation data is no longer valid. Additionally, PRTG requests the value from validuntil in the activation data as well when you activated it with a Paessler PRTG Enterprise Monitor license first on an online system and later switch to an offline environment.

PRTG logoWeb GUI

We replaced our old PRTG gauge logo with a new one that was updated in colour and style throughout PRTG. The logo has also changed in the new UI in various locations, for example, in the tab as the favicon display or as the Monitoring icon.

All parts of PRTGVarious

Various other minor fixes and improvements, updated user manual.

Fixed

Fixed

HPE 3PAR Drive EnclosureSensors

We fixed an issue for the HPE 3PAR Drive Enclosure sensor that reported the error message N/A could not be converted to integer in certain cases. The issue occurred when the drive controller reported an invalid temperature or no temperature at all.

SNMP Disk Free v2Sensors

We fixed an issue for the SNMP Disk Free v2 sensor that displayed the settings Type and Size for the monitored disks in the sensor Settings. Those columns should only be available during sensor creation. The SNMP Disk Free v2 sensor will now only display the columns Type and Size during sensor creation in the result columns.

HPE ProLiant Memory Controller sensorSensors

The HPE ProLiant Memory Controller sensor now supports additional lookups for systems using Adaptive Double Device Data Correction (ADDDC). Previously, the sensor reported an error undefined lookup value (16) in such cases.

Note

Note

Notification deliveryKnown Issues

We currently face an issue with SMTP notification delivery when you have set your Notification Delivery settings to Use direct delivery with the built-in email server (default). This issue occurrs with updating to PRTG version 25.2.106.1114 where email notifications are sent several times instead of only once. Additionally, you will notice an error growl message: Your PRTG core server is currently unable to send email notifications. Check your configuration..

Discontinuation of SSH INodes Free sensorSensors

With this PRTG version we discontinue the SSH INodes Free sensor. We already announced the deprecation of this sensor type with PRTG version 25.2.106.1114. Running SSH INodes Free sensors on your PRTG installation will stop working when you update to this PRTG version. Migrated sensor types from SSH INodes Free to the successor v2 sensor version are not affected. You cannot add the SSH INodes Free sensor anymore when you update to this PRTG version. Please use the successor sensor SSH INodes Free v2 in this case which left its BETA status with PRTG version 25.1.104.1946.

Deprecation of certain sensor types with PRTG 25.x.108Sensors

With this PRTG version we announce the deprecation of the following sensor types: SSH Meminfo, SSH Load Average and SSH Remote Ping sensor. Existing sensor types will continue to run when you update to this PRTG version, however, you cannot add those sensors anymore as new. PRTG will also create an according To Do ticket. For more information on sensor deprecation, please see our Knowledge Base articles: What sensors are deprecated and what are their successors or alternatives? and What do deprecation and discontinuation in the context of sensors mean?

Upcoming sensor migration with PRTG version 25.x.110Sensors

With this PRTG version we announce the sensor migration that will happen with PRTG 25.x.110 for the following sensor types: SSH Meminfo, SSH Load Average and SSH Remote Ping sensor. PRTG will sent an according TO DO ticket with all relevant information. The sensors will be migrated to their successor types SSH Meminfo v2, SSH Load Average v2 and SSH Remote Ping v2 sensor. Those successor sensors left their BETA status with this PRTG release.

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 25.2.108.1279

  • sha256_exe 2A9E7C6E6C33D19002B6842FA9D14C821723C80104E2575B428383A889864CDA
  •  
  • sha256_zip 8FA170B12BE441FFA1B9F4AD2614F22F45A917950C5CD335FDBCECA144C956EE
Lab

Lab

APIPRTG API v2
  • We implemented a new GET endpoint under api/v2/experimental/license in the Systems section of Swagger UI. This endpoint is only accessible if you are logged in as a PRTG administrator. You can receive information about the current PRTG license with the fields start_date, end_date, maintenance_end_date via GET request.
  • We fixed an issue for GET endpoints in PRTG API v2 that returned a 200 OK response with a default set of fields when you, for example, had a typing error in the inheritance parameter. The API will now return a 400 Bad Request in this case with the message the request could not be processed.
  • We added a new filter operator Ancestor ID for experimental list endpoints in PRTG API v2. The filter returns all objects that have the specified ID as an ancestor in their object hierarchy. Affected experimental endpoints are, for example, /experimental/channels and /experimental/sensors.
1
...
45678
...
14

Products

  • Paessler PRTG
    Paessler PRTGMonitor your whole IT infrastructure
    • PRTG Network Monitor
    • PRTG Enterprise Monitor
    • PRTG Hosted Monitor
    • PRTG extensions
      Extensions for Paessler PRTGExtend your monitoring to a new level
  • Icon Features
    FeaturesExplore all monitoring features

Monitoring with PRTG

  • Network monitoring
  • Bandwidth monitoring
  • SNMP monitoring
  • Network mapping
  • Wi-Fi monitoring
  • Server monitoring
  • Network traffic analyzer
  • NetFlow monitoring
  • Syslog server

Useful Links

  • PRTG Manual
  • Knowledge Base
  • Customer Success Stories
  • About Paessler
  • Subscribe to newsletter
  • PRTG Support
  • PRTG Consulting
  • PRTG Feedback & Roadmap

Contact

Paessler GmbH
Thurn-und-Taxis-Str. 14, 
90411 Nuremberg 
Germany

info@paessler.com

+49 911 93775-0

  • Contact us
©2026 Paessler GmbHTerms & ConditionsPrivacy PolicyImprintTrust CenterDownload & InstallSitemap
Home Home Home