We improved the authentication implementation of PRTG to defend against potential timing attacks and username enumeration.
To follow up with the NTLM deprecation process from Microsoft and as a first iteration to support Kerberos for WMI sensors, we have implemented a toggle to use WSMan for WMI connections in the PRTG Administration Tool. In the Probe Settings for Monitoring you will see an additional radio button where you can select Use WSMan for WMI connections, however, DCOM is still activated by default. You can set WSMan for WMI connections for each probe.
In the PRTG settings Credentials for Windows Systems you can select the option Only Kerberos as WMI Authentication Method. To use the Only Kerberos setting, please enable the WSMan protocol on the probe system in the PRTG Administration Tool before. You can also select Negotiate (Kerberos, Fallback to NTLM) in the WMI Authentication Method when WSMan protocol is active. In this case, PRTG will establish a connection using Kerberos authentication.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files.
We updated the German and Spanish language files for certain sensor types.
To give you an improved and accurate view of Maintenance Days Left and Sensors Available, we have removed the widget on the page welcome.htm in PRTG and replaced it with a link to the New UI. The button Need Accurate License Details? links you to the New UI which provides a transparent and consistent overview of sensor usage. In course of this, we have removed the Number of Sensors count on the License Status page in the classic web interface.
We fixed an issue for the SNMP Disk Free v2 sensor that reported a broken error message and could not read the disk when the disk name contained certain language characters. Any non-conforming character in the disk name is now translated into its hexadecimal representation. Please note that you must recreate the sensor for these changes to take effect.
We fixed an issue in the PRTG Administration Tool where strings in buttons e.g. were truncated for certain languages. Affected tabs were, for example, PRTG Application Server and NATS Server when you opened the PRTG Administration Tool in German.
We fixed an issue that occurred in previous PRTG version 26.1.117.1426, where the update would fail in certain special cases if you had a Multi-Platform Probe connected where the NATS server was not installed on the local PRTG core system but on a remote server. The setup error message displayed was: failed to read base configuration.
We fixed an issue for PRTG installation with previous PRTG version 26.1.117.1426 that failed when you have installed PRTG with custom Installation and Data Paths. The update process was initiated, but neither the PRTG Core server service nor the PRTG Database service did start.
We currently have an issue regarding auto-discovery where not all sensors are found and created when you start auto-discovery with specified Credentials for Windows Systems for a certain IP range. The issue occurs when you configure the IPv4 Base, IPv4 Range Start and IPv4 Range End fields for auto-discovery and also enable the Perform auto-discovery for devices/IP addresses already known within PRTG setting.
We currently face an issue in the PRTG API v2 for the new endpoint
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 26.1.118.1342
We improved the SIMATIC S7-300/400 CPU Status sensor (BETA) which now displays the Maximum OB1 Cycle Time in the Specific Sensors Settings if you have set it before during sensor creation. The Maximum OB1 Cycle Time describes the maximum cycle time for the program cycle organization block (OB1) what PRTG uses to calculate the value of the Cycle Ratio channel.
You can try out the experimental SIMATIC S7-300/400 LED Status sensor (BETA) which displays the status of all physical LEDs on the front panel of a SIMATIC S7-300 or S7-400 controller. The sensor will automatically create one channel per LED that is actually available on that monitored PLC model. Depending on the status of the LED, the sensor displays a message for the respective channel, which is mapped via lookup values. For example, Maintenance Required (MAINT) will show the status OK if the LED has the value OFF.
We improved the search method for the SNMP Custom String v2 sensor for search with wildcards and when you have set Interpret Result As to String (default) in the sensor Settings. The sensor has a new setting Search String Contains with the options Simple string (default), Wildcards and Regular expression. You can replace parts of your substring by wildcards, for example ? matches a single character. You can find the returned value in the channel String Found.
You can try out the experimental Proxmox VE Cluster Health sensor (BETA) that monitors the health status of Proxmox VE clusters. Available channels for this sensor type are Quorum Reached, Active Nodes, Online Nodes and Total Nodes. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication. Please note that the channel Ceph Status is optional and is only available when you have configured a Ceph file system before.
With this PRTG version we introduce the new SNMP Windows Service v2 sensor that was rewritten to provide improved reliability and maintainability. This sensor monitors a Windows service via SNMP and uses credentials in Credentials for SNMP Devices that you have to configure in the device settings.
With this PRTG version we support authNoPriv as Authentication Method for SNMP sensors and SNMP version v3. The authNoPriv mode enables you to monitor infrastructures that only allow authentication without encryption. To use this authentication method, you have to select None as Encryption Type in the credentials for SNMP devices to disable encryption.
Various other minor fixes and improvements, updated user manual.
We updated the German and Spanish language files.
We fixed an issue in the device settings for Credentials for Microsoft 365 that occurred when you entered an invalid Tenant ID. In this case, you would receive a bad request error message, however, the changes were saved and you were not able to change any other device settings afterwards.
We fixed an issue for Folder sensors that occurred when you have monitored network shares that contained certain utf-8 special characters in their file names. In the Result of Sensor logfile you could see the following error message: No mapping for the Unicode character exists in the target multi-byte code page.
We fixed an issue for the Ping v2 sensor where the channel Status was not set as primary channel when you had the setting Inverted Error Status enabled.
We fixed an issue for the Microsoft 365 Mailbox sensor when you have selected "...matches regular expression" in the Filter Messages for Subject, Form and Body. The issue occurred in cases when you used an invalid regular expression. The sensor would display an error message that was only partially translated in these cases.
The SSH Disk Free v2 sensor now detects all available filesystems during sensor creation for Linux distributions. Previously, the sensor did not offer and create all available filesystems as channels like its predecessor SSH Disk Free which resulted in missing channels afterwards.
The configuration file of this version is not downwards compatible with previous PRTG versions.
To update to subsequent PRTG versions, you must first install the following PRTG version: 26.1.116.1534 Preview. PRTG 26.1.116.1534 serves as an intermediate version when you want to update from older PRTG versions to subsequent versions. This step is necessary because we had to update our code signing certificates.
PRTG will run into a setup error with the message failed to read base configuration when you update to this PRTG version in certain special cases. This issue happens when you have a Multi-Platform Probe connected where the NATS server is not installed on the local PRTG core system but on a remote server.
We currently face an issue where the update to this PRTG Preview version 26.1.117.1426 fails when you have installed PRTG with custom Installation and Data Paths. The update process is initiated, but neither the PRTG Core server service nor the PRTG Database service start. A possible workaround is to manually copy the content from the default Installation Path C:\Program Files (x86)\PRTG Network Monitor to the custom installation path and restart the services afterwards.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 26.1.117.1426
With this release, version 26.1.117.1437 is also available, as we are currently executing an A/B test. This version will therefore only be displayed for installation if you are in the corresponding group for a PRTG trial installation. Apart from all changes that are included in 26.1.117.1426, this version comes with improvements and new features for our New UI.
Please note that you cannot add a new Multi-Platform Probe version 3.6.1 to this PRTG Preview version 26.1.117.1426. PRTG Preview version 26.1.117.1426 introduces an integrated NATS Server Setup to support the PRTG Database. The integrated NATS server changes the supported NATS authentication to NATS server Access Identifiers using NATS NKeys. Multi-Platform Probe 3.6.1 does not support the creation of NATS server Access Identifiers yet, however, we will add support in a later version.
Your existing Multi-Platform Probes are not affected and will be migrated automatically to the integrated NATS server.
With this PRTG version we introduce PRTG Database, developed for data processing and storage in PRTG as a first Beta release. PRTG Database is designed to increase efficiency and speed, especially in large installations with many sensors and data points. It is an alternative to file system storage and uses PostgreSQL to store raw monitoring and configuration data. The PRTG Database will install files and components automatically when you update to this PRTG version, however, it is currently deactivated by default.
Important:
PRTG will create the Database Health (Autonomous) sensor automatically when you update to or install this PRTG version 26.1.117. The sensor is created within the PRTG Core Server group and monitors the PRTG Database service as a first iteration. The sensor will report an error if the PRTG Database service is not running.
You can try out the experimental SSL/TLS Security Check sensor which is the successor to the SSL Security Check sensor. The SSL/TLS Security Check sensor supports modern protocols to ensure secure encrypted connections. Unlike the old sensor, TLS 1.3 is also supported. TLS 1.2 and TLS 1.3 are set as accepted (default) in the sensor settings Security Evaluation, whereas weaker protocols (SSL 3.0, TLS 1.0, TLS 1.1) are set to denied (default). This sensor type can also be created on the Multi-Platform Probe.
You can try out the Proxmox VE Node Performance sensor that monitors performance metrics and status of Proxmox VE host nodes. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication.
We fixed an issue where certain pages were displayed for a few seconds in the classic web interface. This issue happened sporadically and the new UI was displayed after automatic or manual refresh of the pages. This issue could affect the Maps and Reports pages, among others.
You can now enter and save notes in the new Comments tab which we have implemented for each monitoring object (Probe, Group, Device, Sensor level). You will receive a success message after saving your changes. Please note that the new Comments tab is not yet available on Mobile view. If you have existing comments in the classic web interface for that object, you will see the comments now also in the new UI.
We fixed an issue that occurred on the sensor Channel Overview page where unknown errors would be displayed. The issue happened after a certain page refresh interval, that is, after a page refresh you could observe an unknown error message toast.
We fixed an issue for Single Sign-on where it was not possible to log in with a Single Sign-on user when you updated to the previous PRTG Stable version 26.1.116.1498 and when you had Single Sign-on configured for your PRTG. The login failed and the page no longer worked. The error message too many redirects was displayed in those cases. If necessary, you may need to clear your browser cache and cookies.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 26.1.116.1534
The Cisco WLC Access Point Overview sensor left its BETA status and is now fully supported. We introduced this sensor type as experimental sensor with PRTG version 24.3.98.1210. This sensor monitors your access points that are connected to your Cisco Wireless LAN Controller (WLC).
The PRTG Data Hub sensors, that is PRTG Data Hub Process sensor, PRTG Data Hub Traffic sensor and PRTG Data Hub Rule sensor, left their BETA status and are now fully supported with this PRTG version. We introduced those sensor types as experimental sensors with PRTG version 24.3.100.1361 in order to monitor a PRTG Data Hub instance.
The Port v2 sensor left its BETA status and is now fully supported. We introduced this sensor type as experimental sensor with PRTG version 22.4.80.1553. This sensor combines the features of the Port sensor and Port Range sensor and monitors a network service by connecting to one or more of its TCP/IP ports.
The SSH INodes Free v2 sensor left its BETA status and is now fully supported. We introduced this sensor type as experimental sensor with PRTG version 24.3.100.1361. This sensor monitors the free index nodes on disks of Linux/Unix and macOS systems via Secure Shell (SSH).
We improved the usage of lookups created by PRTG that now implement the necessary syntax to reference the schema. This shows you information about the formatting when you work with lookup files in an editor program. For example, when you check the created lookup in the \PRTG Network Monitor\lookups\custom folder with an editor program after you have added an SNMP Library sensor before, you will now see additional information about the XML schema. This change applies only for newly created lookup files.
Various other minor fixes and improvements, updated user manual.
We fixed an issue that could cause internal nodes to be deleted via API call. Internal nodes required for your PRTG installation can no longer be deleted now via API call.
You can now delete an object only when you have the according access rights to that object, regardless if you have write or full access to the parent node. Previously, there was a check for the access rights only on the parent node. If you do not have write access to all the objects that you want to delete, you will receive an access denied error for this operation.
We improved the behavior of PRTG auto-update concerning the available PRTG versions.
We fixed an issue where in certain cases an enabled Geo Map could lead to ajax timeout errors or slow performance in the PRTG web interface. You could observe this issue when your PRTG core server was blocked in your firewall for outgoing connections and PRTG would try to reach the geolocation service continuously. In the Core.log you could also read an error log entry GetGeoLocation: failed to read geolocation.
We fixed an issue for email Notifications that occurred in certain cases in the previous PRTG version where email notifications were not received although they reported the status Status sending Email: OK in the PRTG system information.
We improved the stability of PRTG local and remote probes that ran into a higher memory consumption in certain cases in the previous PRTG versions. You could observe access violations or exceptions in some cases in the Probe log and that the probe service stopped working due to the high memory consumption. Restarting the probe service only helped temporarily in such cases.
We fixed an issue for remote probes where in certain cases the content in the Log tab was not rendered and therefore the Log tab was displayed as empty.
We fixed an issue for reports where the first line of a report saved in .csv file format displayed the first line in unresolved characters and was not readable. The issue occurred when you have set your PRTG language to Russian, Japanese or Chinese and ran a report including data tables to be saved as .csv file.
You will now be able to log in with your Single-Sign on user account again after you have changed your license key or after server migration. In previous PRTG versions, the user account for a Single-Sign on user was paused after you have transferred to a new license and login was not possible.
We fixed an issue for the HPE3 PAR Drive Enclosure sensor where the drive controller reported an invalid temperature or no temperature at all in certain cases. The sensor will now ignore drives with missing or invalid temperatures instead of going into an error state.
We fixed an issue where in some cases changing settings of certain custom sensor types resulted in a PE270 error with the message An error occurred. To resolve this issue, try to pause and resume the sensor or check your settings. In cases where pause and resume did not help, a PRTG core server restart would make those sensors run again. Sensor types affected were, for example, Modbus TCP Custom sensor and MQTT Subscribe Custom sensor.
The option Filter by Message in the WMI Event Log sensor settings under Filter Event Log Entries is now working again as expected. When you disabled the Filter by Message option and saved the settings, the log entries would still only be returned for this filter option
We fixed an issue for the Multi-Platform Probe Connection Settings in the PRTG Setup menu that you could not save anymore in certain cases. For example, when you changed the connection settings from Allow multi-platform probe connections to Do not allow multi-platform probe connections (default), the changes would not be applied after a Core restart. You could also observe an error message in the Multi-Platform Probe Connection Health (Autonomous) sensor that displayed Error caused by lookup value 'Disconnected' in channel 'NATS Connection State' although the NATS server was installed and running.
With this PRTG version we inform you about the upcoming sensor migration of the SSH INodes Free sensor to its successor SSH INodes Free v2 sensor in PRTG 25.x.106. You will receive an according To Do ticket in PRTG with this PRTG version when you run SSH INodes Free v1 sensors. This tickets informs you also about upcoming custom device template migration from the existing sensors to the new sensors.
For more information about sensor migration, see the following Knowledge Base article: https://kb.paessler.com/en/topic/91901.
You will notice that PRTG logs several entries for exceptions in the Core.log in certain cases when you change the graph period in the Graph Settings under User Interface in the System Setup. The issue occurred in the previous PRTG version 24.4.102.1351. The log entries with the message Exception: Wrong period in cache appear after the automatic core server restart when you have changed and saved graph settings before. We will deliver a fix for this issue with the upcoming PRTG versions.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 25.1.104.1841
We improved the performance of the PRTG application server that caused a higher memory usage especially for larger PRTG installations in the previous PRTG versions.
You will now see the message in your acknowledged sensors about who acknowledged it with an according time stamp as well as the error message itself. This information was missing in the previous PRTG versions when you did not enter a text for an acknowledge message.
We fixed an issue for the error page with the message The selected object cannot be used here or it does not exist that is displayed when you, for example, want to clone or delete a not existing report. In this case the mentioned error page is displayed, however, the redirect would link you to the PRTG welcome page. You will now be redirected back to the page you came from, in this case the Reports tab.
We improved the drop down menu for the tab Logs in the PRTG New UI. In previous PRTG versions, you had to scroll down in the menu when you clicked on Choose Filter in order to see the option Status Message Related. The drop down menu has now an extended view to display all options without scrolling.
We improved the objects Detail page when you navigate to the Monitoring overview. Instead of just the content list, you can now scroll through the whole page. The Actions button will stay in place when you scroll through the page.
We fixed an issue where not all channels of sensors that belong to the probe device of a remote probe were displayed in the new UI. This issue occurred in previous PRTG versions after you have approved a new incoming remote probe.
We fixed an issue that occurred, when you clicked on a sensor in the navigation tree under Monitoring. The sensor overview page would open on the right side. When you closed the split view for the sensor overview page and clicked on the same sensor in the tree again, the overview page would not open.
We have set the HTTPOnly and SameSite flag for the cookies created by PRTG to strengthen secure transmissions.
We improved the security handling for API tokens regarding interactive web sessions by restricting access for API tokens to certain endpoints.
Single Sign-on users are now able to create API keys that can be enabled in the Single Sign-on account settings. As a prerequisite, SSO must be configured in PRTG and an SSO group must exist. You can then enable the new feature Enable API Keys for SSO Users in the Single Sign-on user group settings, which is disabled by default. Additionally, this setting includes a field SSO API Key Lifetime (Days) where you can set the days for how long the API key is valid. When SSO API keys expire after the configured lifetime, the relevant API keys will be cleaned up automatically. As a Single Sign-on user, you can use the SSO API keys also for API authentication.
We have implemented a character limit of 240 characters for the Display Name in the User Account Settings. You cannot save changes if the Display Name exceeds the character limit and you will receive an error with the message The display name cannot exceed 240 characters.
Various other minor fixes and improvements, updated user manual.
We updated the German, Spanish and Dutch language files.
We updated the French, Portuguese, Russian, Chinese, Japanese and Dutch language files for certain sensor types.
We fixed an issue where in certain cases activating an incorrect license key for PRTG Subscription licenses led to access violations in the Core.log file.
We fixed an issue where the License Name was cut off in certain cases on the License Status page when you did use special characters, in this case quotation marks ", in the license name.
We fixed an issue for Cloud HTTP v2 sensors that reported the error message The queried field "message" is empty in certain cases. The issue also happened when you monitored different endpoints in various Azure regions.
We improved the error handling for file system sensors, for example, Dell EMC Unity File System v2 sensor, to better map error messages like The specified network name is no longer available.
We removed the deprecated setting Basic256 in the Security Policy section of the Credentials for OPC UA. This setting was deprecated due to the used hash algorithm Sha-1. Please note that your OPC UA sensors will report an error message if you have configured the Basic256 setting and update to this PRTG version.
We fixed an issue for the scaling factor sensor channel setting where you can enter a multiplication or division scaling factor for sensors with custom units. The issue occurred, when you have configured a scaling factor for your sensor and at the same time entered channel limits. After saving the changes, you could observe that the channel limits were either divided or multiplied with the value you have entered as scaling factor.
We fixed an issue for the SNMP Windows Service sensor that occurred in certain cases when you have used this sensor type in a device template. For example, when you have configured a device template with the SNMP Windows Service sensor and have set an include/exclude filter for a certain service and run an auto discovery later on a device to create the sensors. When you delete one of those sensors afterwards and run the device template again, the deleted sensors would not be created.
We fixed a compatibility issue for Veeam Backup Job Status and Veeam Backup Job Status Advanced sensors that did not support Veeam 13 for Veeam Backup Enterprise Manager and Backup Server. The sensors reported an error with the message that the JSONPath is incorrect in previous PRTG versions.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 26.1.116.1487
You can try out the experimental Proxmox VE Virtual Machine Status (BETA) sensor that monitors performance metrics and status of QEMU virtual machines on Proxmox VE clusters. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication.
You can try out the experimental Proxmox VE Container Status (BETA) sensor that monitors performance metrics and status of LXC containers on Proxmox VE clusters. To use this sensor type, please enter the Credentials for Proxmox in the device settings with API token authentication.
We implemented a new setting for the SNMP Custom String v2 (BETA) sensor in the Specific Sensor Settings, named Interpret Result as. This setting basically converts the result from the SNMP endpoint into a string. You can select String (default), MAC address and IPv4 address for this setting. The sensor message will then show the format of the setting you have selected before, for example for MAC address it will display "01-02-03-04" as server response.
The Custom v2 sensor now supports string-encoded BITS values, for example MAC addresses, that are converted to a numeric format. Parsed BITS values will work with existing channel configurations.
You can try out the experimental SSL/TLS Certificate sensor (BETA) which is the successor to the SSL Certificate sensor and which was rewritten to also work on the Multi-Platform Probe. This sensor type monitors the certificate of a Secure Sockets Layer (SSL)/Transport Layer Security (TLS) secured connection. Please note that this sensor does not yet support the Use SOCKS proxy setting.
We fixed an issue for dialogues that disappeared partially behind the resize handler in the split view of the new UI. For example, when you have created a new device, you will receive a pop up dialogue success message object successfully created which could disappear partially behind the resize bars.
You are now able to delete multiple objects in the Sensor list or Device list via bulk edit selection. You will see a confirmation dialogue that asks you if you want to cancel or confirm the deletion of the selected objects. You will receive an according error message if you do not have the necessary rights to delete certain objects.