• Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
 
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
Paessler
                    - The Monitoring Experts
  • Products
    • Paessler PRTG
      Paessler PRTGMonitor your whole IT infrastructure
      • PRTG Network Monitor
      • PRTG Enterprise Monitor
      • PRTG Hosted Monitor
      • PRTG MSP Edition
      • PRTG OT Edition
      • PRTG extensionsExtensions for Paessler PRTGExtend your monitoring to a new level
    • Icon Features
      FeaturesExplore all monitoring features
      • Maps & dashboards
      • Alerts & notifications
      • Multiple user interfaces
      • Distributed monitoring
      • Customizable reporting
      • Network Topology
  • Solutions
    • By TeamFor your organization size
      • Small Business IT
      • Mid-Market IT
      • Enterprise IT
      • MSP Network Monitoring
    • Industries
      By IndustryFor your business sector
      • Industrial
      • Healthcare
      • Energy
      • Government
      • Education
      • Data Center
      • Finance
    • IT Topics
      By Use CaseFor every technical scenario
      • Network Monitoring
      • Server Monitoring
      • OT Monitoring
      • Distributed Monitoring
      • Network Topology Mapping
      • SNMP Monitoring
      • Bandwidth Monitoring
  • Pricing
  • Resources
    • Getting Started
      Getting StartedModules for self-paced learning
    • How-to Guides
      How-to GuidesGet the most out of PRTG
    • Videos & Webinars
      Videos & WebinarsLearn from Paessler experts
    • Case StudiesProven results across industries
    • PRTG ManualFull documentation
    • Knowledge Base
      Knowledge BaseShare community knowledge
    • PRTG Sensor Hub
      PRTG Sensor HubGet sensors, scripts & templates
    • Trainings
      PRTG TrainingLearn how to work with PRTG
  • Partners
    • Icon Handshake
      Become a PartnerFor resellers and channel partners
    • Icon MSP
      Become an MSPDeliver monitoring as a managed service
    • icon partner
      Partner PortalLog in to your partner account
    • Deal Registration
      Deal RegistrationRegister your sales opportunities
    • icon search
      Find a PartnerFind partners selling Paessler products
    • icon technology
      Technology AlliancesSee Paessler technology partnerships
    • Partner HubTools for Your Success
  • Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
  • Get a quote
  • Free trial
  1. Home>
  2. Paessler PRTG>
  3. Version history>
  4. Preview release notes

PRTG Release Notes:
Preview Channel

Early Access to New Features

  • Preview versions give you early access to the latest features and improvements before they reach the stable channel. These versions have been thoroughly tested in our labs, but may still contain limitations in certain monitoring configurations. We do not recommend using preview versions in production environments.
  • To update your PRTG installation with the latest preview version, use the Auto-Update feature: In the PRTG web interface, navigate to Setup | Auto Update.
  • Looking for the most reliable version for your live environment? Check out our Stable Release Notes.
Stable Channel

PRTG Preview Version 26.2.120.1442

Release date: June 2, 2026
Changed

Changed

Activated PRTG Database (BETA)Server

In case of a manual update to this PRTG version and if you have previously activated the PRTG Database, you will see an installation window with the message that the installation has stopped in order to keep your existing data. This is due to a new schema update in this PRTG version. The installation window will provide further instructions on how to proceed with the update.

The auto-update process will currently stop when you update to this PRTG version if you have previously activated the PRTG Database and have existing data. This issue affects you if you have set your auto-update to Automatically download and install in the Software Auto-Update settings. PRTG will create a TO DO ticket Error: The update cannot continue due to a change in the database schema if you run into this issue.

Fixed

Fixed

Database Health (Autonomous) sensorSensors

We fixed an issue where the Database Health (Autonomous) sensor ran into error status when you updated to the previous PRTG Preview version 26.2.120.1367. The associated Database service also stopped and could not be started in those cases.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 26.2.120.1442

  • sha256_exe 5DFDFAF2C330E37DB4E71F5E293FF6D6A0E03FA9FC6AAADDE153E396BDD6AB65
  • sha256_zip 8BCCEB5B9F20E1E0C5E5A87BEAD78BE7C84B1CBA230679F45EBA7230200E4953

PRTG Preview Version 26.2.120.1367

Release date: May 5, 2026
New

New

SNMP Custom String v2Sensors

With this PRTG version we introduce the new SNMP Custom String v2 sensor that monitors a string returned by a specific object identifier (OID) via the SNMP. The sensor interprets the SNMP value returned by the OID as a string, a MAC address, or an IPv4 address and shows the interpreted value in the sensor message. We introduced this sensor as experimental BETA sensor with PRTG version 26.1.116.1498.

SNMP Printer v2Sensors

We added the new SNMP Printer v2 sensor to monitor printer status, consumables, and operational metrics via SNMP. The sensor supports IPv4 and IPv6. Depending on the monitored printer, the sensor creates the channels Total Pages Printed, Cover Status, Tray Status and Supply Status. The sensor message displays the printer console output. If no printers are defined in the device table, the sensor will report an error. This sensor introduces 1-based numbering for printer units, as well as removing ranged lookups in favor of direct percentage and lookup values.

Improved

Improved

WebserverSecurity

We hardened PRTG against possible cross-site scripting attacks through certain parameters on the public login page.

All parts of PRTGVarious

Various other minor fixes and improvements, updated user manual.

Changed

Changed

Custom sensorsSensors

We updated the list and location of the example scripts for custom sensors in the PRTG program directory. This removes all Demo scripts from the pre populated custom scripts directory. Scripts that were not deemed as risky are preserved under the examples script directory. Additionally, we have updated the example scripts for Script v2 to follow a more modern structure. Please note that in course of this change that we removed any .dll and .exe demo binary from PRTG.

Fixed

Fixed

NATS setupServer

We fixed an issue that occurred when you updated to previous PRTG version 26.1.118.1380 and when you have previously set your local storage of data files and monitoring database folder in the PRTG Administration Tool to root of a drive, e.g. C:\. In this case, you would receive an error The PRTG installation stopped due to a NATS setup error. "NatsManager.exe: Failure during NATS configuration with return code=95". This error was also logged in setup.log, along with an initiated rollback of the version. Despite this, the PRTG Database service continued to run, but without the NATS installation and as a result, PRTG was no longer usable.

Ping v2 sensorSensors
  • We fixed an issue where having multiple ping sensors targeting the same host caused all raw ICMP sockets to receive all answers, resulting in an error message Received packet had unexpected identifier or sequence number in the Result of Sensor logfile. The sensor also wrongly reported packet loss in case of packets received with a mismatching type or identifier.
  • You are now able to use a new setting for the Ping v2 sensor Error Status Handling, to define an evaluation method to display negative results. The sensor immediately shows the Down status based on channel lookups for the setting Enter the down status immediately (default).
DNS v2 sensorSensors

We have improved the DNS v2 sensor regarding filtering reliability and result consistency. Null MX records are now correctly displayed as 0 if a domain does not accept emails, and DNS records of the same type are now sorted alphanumerically to ensure consistent output across repeated requests. Record values are trimmed before filter matching to prevent whitespace-related mismatches. A new Match the full result exactly filter mode has been added for record types whose values naturally contain commas, such as TXT and NAPTR. The internal connectivity check now queries the root domain for NS records instead of using a localhost ANY query, improving compatibility with modern DNS servers.

Note

Note

PRTG Database migrationKnown Issues

We currently face an issue where it is not possible to log in via Single Sign-on after enabling PRTG Database for data migration. If you have set up Single Sign-on before and migrated your configuration to PRTG database, the login with Single Sign-on would fail afterwards. In the User Group Settings you could observe that the SSO Group Claim was missing. A possible workaround is to set up a new Single Sign-on user group.

PRTG installerKnown Issues

Please note that with updating to this PRTG version, the auto-update process takes longer because it includes the PRTG database and related components, which increase the size of the PRTG installer. We strongly recommend that you do not restart PRTG during this process and wait until the update is complete.

Database Health (Autonomous) sensorKnown Issues

We currently face an issue where the Database Health (Autonomous) sensor runs into error status when you update to this PRTG version. The associated Database service has also stopped and cannot be started in those cases. We are working on a fix for upcoming PRTG versions.

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 26.2.120.1367

  • sha256_exe 6699AE59EB6C357160B0AE01BF3075D07D65271F90A51390772AED4B08C34F81
  • sha256_zip 626302961C7B6B66F00D15B368A8F1E65967FAF6009D4C3B50C16B1E8D916E82
Lab

Lab

PRTG DatabaseServer
  • We fixed an issue where certificates created by NATS Manager were never deleted from the Windows Certificate Store. The certificates NATS Server for Paessler PRTG and Paessler NATS Manager are now properly removed when PRTG including NATS is fully uninstalled, when an initial installation is canceled or rolled back, or when an update is rolled back to a previous PRTG version without PRTG Database.
  • With this PRTG version, the PostgreSQL Database installer will no longer install the pgAdmin tool if you have already installed a PRTG version with the PRTG Database. Your installation will proceed as expected, but the pgAdmin tool will no longer be updated in this case.
  • We fixed an issue where setting up the PostgreSQL database with a custom password failed if the password contained certain special characters. The installer now validates both the username and password against the allowed character sets in real time. The PostgreSQL username is restricted to alphanumeric characters only, while the password additionally allows the following special characters: _ ! . + - = ~. An error message is displayed and the user cannot proceed until invalid characters are removed. The setup screen now also clearly displays these constraints to guide users during configuration.
  • We have updated our PostgreSQL database from version 18.1 to 18.3.
Data migrationServer

We fixed an issue where sensor tags were lost after migrating configuration and monitoring data to the PRTG database. This caused sensors to become invisible in tag-based filters, making libraries and reports that rely on tag filtering no longer work as expected. This issue applied to the WMI Free Disk Space (Multi Disk) sensor, for example.

SIMATIC S7-300/400 CPU Restart Overview sensorSensors

We improved the retry mechanism for the SIMATIC S7-300/400 CPU Restart Overview sensor to reduce false alerts caused by intermittent errors when querying data from a PLC via S7. Previously, the PLC would occasionally return a CPU : Item not available error, causing the sensor to go into a down state for one or more scans before recovering, despite the PLC working correctly the whole time. When the PLC is too busy to serve the request of the sensor, the request is now retried after a delay of 100 ms, with a configurable maximum delay of up to 1000 ms.

Channel unitsNew UI

We fixed an issue where the Channel Unit Configuration did not display the correct units for Disk size, File size and Memory size.

Device treeNew UI

You can now move devices into different groups and reorder objects within a parent in the new UI. Active monitoring objects are now highlighted across the full row width for better visibility, and a context menu has been added to streamline navigation and management actions.

Welcome pageNew UI

You are now able to use our new AI Chatbot Max on the Welcome Page in PRTG New UI. Clicking the Start Chatting button opens a slide-in panel on the right side of the page, where you can interact with the chatbot. MAX AI has in-depth knowledge of PRTG and is ready to assist you with questions and troubleshooting directly from the Welcome Page.

APIPRTG API v2
  • With this PRTG version we introduce parameter support for the metascan endpoint /experimental/{id}/metascan to create a NetApp System Health sensor via POST request on /experimental/devices/{id}/sensor. The metascan endpoint now accepts a request body with parameters as defined in the schema, allowing the NetApp System Health sensor metascan to be triggered successfully via URL parameters.
  • We fixed an issue where consecutive calls to /experimental/schemas/{deviceID} returned inconsistent results for the same sensor. Affected sensors, particularly Dell EMC sensors such as paessler.dellemc.storage_filesystem_v2_sensor and paessler.dellemc.storage_capacity_v2_sensor, could alternately appear as creatable with no hints in one call and non-creatable with a MissingCredentials hint in the next. Consecutive calls to the schema endpoint now consistently return the same results.
  • We fixed an issue where the PRTG application server responded with a panic.log file including the message panic: runtime error: invalid memory address or nil pointer dereference. The issue occurred when you executed a GET request on endpoint /experimental/schemas/{parent}/post with parent=40 (local probe) and kind=snmpcustomtable.

PRTG Preview Version 26.2.119.1662

Release date: April 21, 2026
Improved

Improved

PRTG installerServer

We have improved the runtime performance of the PRTG installer, which has included the PRTG database since PRTG stable version 26.1.118.1380. This change applies to all new installations.

Fixed

Fixed

Custom SensorsSensors

We fixed an issue that occurred in previous Preview version 26.1.119.1641 where placeholders for credentials in custom sensors were not resolved anymore in certain cases. This issue could have led to authentication failures and the sensors to go into an error state.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 26.2.119.1662

  • sha256_exe 6781DB15B7005A7D4891B2365E07FB547C14759A62151EE71E4B201C94A03719
  • sha256_zip E2860C55595BF4E1769264D77E083233ECE5A3E4F3278DDCD2C38072AC0E6BD4
26.2.119.1663Installer

With this release, version 26.2.119.1663 is also available, as we are currently executing an A/B test. This version will therefore only be displayed for installation if you are in the corresponding group for a PRTG trial installation via website download. Apart from all changes that are included in 26.2.119.1662, this version comes with improvements and new features for our New UI.

PRTG Preview Version 26.2.119.1641

Release date: April 9, 2026
New

New

SNMP RMON v2 sensorSensors

With this PRTG version we introduce the new SNMP RMON v2 sensor that was rewritten to work also on the Multi-Platform Probe. The SNMP RMON v2 sensor monitors traffic on a device using the Remote Monitoring (RMON) standard via SNMP. In the Specific Sensor Settings you have the option to edit the settings Description or 64-bit on request. This information is collected during sensor creation and if 64-bit counters are enabled in the compatibility settings.

ReportsServer

With this PRTG version we introduce the PRTG Installation Report, a new built-in report available by default in all standard PRTG installations under Reports menu. With this report you can collect data about your PRTG installation, including license information, system health and optimization recommendations. The report can be generated on-demand or scheduled for automated delivery. The report supports PDF, CSV and HTML formats.

Improved

Improved

WebserverSecurity
  • We performed sanitization on HTTP error responses to prevent information disclosure.
  • We performed sanitization on the URL Path in HTTP error responses to prevent information disclosure.
  • We enforced input sanitization on object name parameters to defend against possible Cross-Site Scripting.
Microsoft 365 Mailbox sensorSensors

The Microsoft 365 Mailbox sensor now supports the setting Validate Latest Email, like for example, the IMAP sensor. The sensor will use the latest email from the filtered messages. If no filters are configured, all messages are taken into account. You can configure warning or error states based on the Subject, From or Body settings. Additionally, you can set the sensor to Down or Warning status based on age for the latest email.

All parts of PRTGVarious

Various other minor fixes and improvements, updated user manual.

Changed

Changed

System StatusWeb GUI

To be consistent with our changes in PRTG version 26.1.118.1380 to display information about sensor usage and licensing in the New UI, we removed the Number of Sensors part under License Information on the PRTG System Status page.

Fixed

Fixed

PRTG Core serviceServer

We fixed an issue where the PRTG core service used a large amount of memory in rare cases which caused the system to run out of memory in the end. You could find the error message out of memory in the core log file in such cases.

Geo mapServer

We fixed an issue where in certain cases an enabled Geo Map could lead to ajax timeout errors or slow performance in the PRTG web interface. You could observe this issue when your PRTG core server was blocked in your firewall for outgoing connections and PRTG would try to reach the geolocation service continuously. A possible workaround was to disable Geo maps.

NetApp SnapMirror v2Sensors

We fixed an issue for the NetApp SnapMirror v2 sensor which regularly went into an error state and did not return any values for certain channels. The ONTAP API omitted transfer fields for continuously synced relationships and the sensor would handle the missing values as error. The issue happened when you used ONTAP with SnapMirror Active Sync and Consistency Groups.

API KeysPRTG MultiBoard

We fixed an issue for Desktop Client and MultiBoard related API keys that you can create in PRTG via Add API Key for PRTG MultiBoard button. The issue happened when you started the Single Sign-on login flow calling getdesktoptoken.htm. The API key that was returned from the endpoint did not work for Single Sign-on content in those cases.

Auto-discoveryWeb GUI

We fixed an issue where Run Auto-discovery with Templates led to an error (bad request) when you selected device templates via multi edit. Previously, it was only possible to select device templates on the first page of the pop-up window. As soon as you selected a device template on the second page or beyond, an error message appeared stating no device template had been selected.

Note

Note

Custom SensorsKnown Issues

We currently have an issue where placeholders for credentials in custom sensors are not resolved in this PRTG version, which can lead to authentication failures and cause the sensors to go into an error state. We are working on a fix with the highest priority and will deliver an update soon.

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 26.1.119.1641

  • sha256_exe B12238C40F9963CB04584261A9EA147EE4040F99777819C48AFC8AB15F004C11
  • sha256_zip CB4D8FE9A8CF2F68D891FD8DF639F23EB0F104B74F1BAC14C82D46CC89859748
Lab

Lab

PRTG Database installerServer
  • We fixed an issue when the installation was cancelled in certain cases either manually or due to an error. The PRTG installer will now inform you about the process and the next steps with the message: Roll back of all changes done within this installation finished. Please reboot your system.
  • We fixed an issue that occurred if you canceled the installation or rolled back to the previous PRTG version. In that case, the PRTG Administration Tool could no longer be started because the .exe file was no longer present.
  • We fixed an issue that occurred in certain cases if you had PRTG installed with a Multi-Platform Probe connected and updated to a PRTG version that includes the PRTG Database. After updating, the NATS service was stopped and could not be started again. Additionally, the NATS server.log file was not created. In the Windows Event Logs you could find the following error: The service did not respond to the start or control request in a timely fashion.
SIMATIC S7-300/400 CPU Status sensor, SIMATIC S7-300/400 CPU Restart Overview sensorSensors
  • We fixed an issue for the SIMATIC S7-300/400 CPU Status (BETA) and SIMATIC S7-300/400 CPU Restart Overview (BETA) sensor that did not display any data results in certain cases. The issue happened because the sensor did not finish the scan for some monitored PLCs.
  • We fixed an issue for the SIMATIC S7-300/400 CPU Status (BETA) and SIMATIC S7-300/400 CPU Restart Overview (BETA) sensor that reported an error message The buffer supplied is too low to accomplish the operation in certain cases. The issue happened for S7-410-5H controllers when the sensor failed to read the diagnostic buffer.
SNMP Custom String v2 sensorSensors
  • We added a new setting Numeric Extraction to the Specific Sensor Settings of the SNMP Custom String v2 (BETA) sensor, which allows you to locate numbers inside a string from the SNMP device by using regular expressions. The sensor then displays the result in an additional channel: Extracted Number.
  • We have improved the SNMP Custom String v2 sensor by changing the primary channel from Response Time to String Found. The Response Time channel did not display a meaningful error message if you used too many wildcards in the Search String setting. The primary channel String Found will display The search string contains too many wildcards in this case.


  • Important: To get the new primary channel String Found, you need to create this sensor again.
SNMP Traffic v2Sensors

We fixed an issue for the SNMP Traffic v2 sensor that wrongly displayed 4 GBit/s as a result for unconnected ports in certain cases. The issue happened mostly for SNMP version v1 or high speed interface connections. The sensor will now display the status Unknown correctly for non-available entries instead of a wrong value.

APIPRTG API v2
  • We fixed an issue where the api/v2/settings/public endpoint did not return the correct language upon GET request. Previously, only en-US was returned for the language field. The endpoint will now correctly display the language you have configured in the PRTG webinterface settings.
  • We have improved the endpoint /experimental/objects/{id}/clone with better documentation in Swagger UI, for example. The deprecated endpoint clone endpoints experimental/devices/{id}/clone was removed.
  • We fixed an issue in PRTG API v2 for the endpoint api/v2/channels/{id} where for some channel items the name field was returned with an empty string.
  • We fixed an issue for the /experimental/schemas/{id}/get endpoint that did not handle the readonly property correctly for Read Only users that have the right to acknowledge alarms.
  • We renamed the PATCH endpoint to /experimental/sensors/{id} to be consistent with other resource endpoints that use the object plural.
  • We have updated the endpoints POST /experimental/devices/{id}/sensor and POST /experimental/devices/{id}/metascan in PRTG API v2 to now support all sensor kinds. Previously, only a selected set of fully tested sensors were allowed. With the sensor creation flow working reliably, the whitelist restriction has been removed, making sensor creation available for all supported sensor kinds without limitations.
Device treeNew UI

We fixed an issue for the Device Tree in the New UI that displayed an additional Add Sensor button when you entered a search string in the search field.

MonitoringNew UI

We fixed an issue for the object tree under Monitoring where object calculation did not work properly for groups that contained only empty objects (groups or devices) and no sensors.

ObjectsNew UI

You are now able to use the following Device Action buttons via context menu: Reorder Tree, Copy and Paste. After you have copied an object, a success message appears. The same applies to the object once you have successfully pasted it. If you do not have the necessary access rights to an object, the buttons in the context menu will appear disabled and display the text no permission.

User sessionNew UI

We fixed an issue where in certain cases an unknown error occurred with the message Something went wrong. Please refresh your browser or try again later. The issue in the new UI happened sporadically and in cases when you closed the browser and opened PRTG again with a page using iframes.

PRTG Home pageNew UI

We improved the Home page in wording and display of content to match the user type that is logged in to PRTG.

PRTG Preview Version 26.1.118.1346

Release date: March 13, 2026
Fixed

Fixed

Auto-discoverySensors

We fixed an issue for auto-discovery that did not work when you used Credentials for Windows Systems with a configured IP range for your auto-discovery group and when you updated to previous PRTG version 26.1.118.1342. PRTG would initiate the auto-discovery process, however, the WMI sensors were not created afterwards.

Please note that for the new option to use WSMan protocol for WMI connections with Only Kerberos as authentication method, you have to select Use DNS names (default) for Name Resolution when you run an auto-discovery.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 26.1.118.1346

  • sha256_exe 21F3D9DD7D323C57463F23CC33A4A6B8485DED9D38AC7B38302C212E10924120
  • sha256_zip 9BFCA6C871B2397F0A6C8DBD304B5B7A2040F2B543D6F562434342061DF0E066
12345
...
14

Products

  • Paessler PRTG
    Paessler PRTGMonitor your whole IT infrastructure
    • PRTG Network Monitor
    • PRTG Enterprise Monitor
    • PRTG Hosted Monitor
    • PRTG extensions
      Extensions for Paessler PRTGExtend your monitoring to a new level
  • Icon Features
    FeaturesExplore all monitoring features

Monitoring with PRTG

  • Network monitoring
  • Bandwidth monitoring
  • SNMP monitoring
  • Network mapping
  • Wi-Fi monitoring
  • Server monitoring
  • Network traffic analyzer
  • NetFlow monitoring
  • Syslog server

Useful Links

  • PRTG Manual
  • Knowledge Base
  • Customer Success Stories
  • About Paessler
  • Subscribe to newsletter
  • PRTG Support
  • PRTG Consulting
  • PRTG Feedback & Roadmap

Contact

Paessler GmbH
Thurn-und-Taxis-Str. 14, 
90411 Nuremberg 
Germany

info@paessler.com

+49 911 93775-0

  • Contact us
©2026 Paessler GmbHTerms & ConditionsPrivacy PolicyImprintTrust CenterDownload & InstallSitemap
Home Home Home