Credentials like passwords in the PRTG configuration file are now masked when you use the option Include configuration file (contains passwords) for Send Logs to Paessler in the PRTG Administration Tool in order to send a support bundle. When you have a larger configuration file, e.g. 355 MB and run the PRTG Administration Tool as a 32 bit version, you will receive a message that PRTG was not able to hide encrypted passwords in the configuration file. The same behavior applies when you want to send a support bundle with a broken configuration file. You will then be asked if you still want to include the configuration file containing passwords or not.
Please note that currently is not possible to start the Administration Tool for a Remote Probe running on a 64-bit operating system. As a workaround go to the Program Files (x86) folder, open the PRTG Network Monitor folder, and run the 32-bit version of the Administration tool. We will deliver a fix for this issue in the upcoming PRTG versions.
You will now see a log entry in the History tab of a device when you have enabled or disabled the inheritance of an object. For example, if you enable the Inherit From feature toggle for Credentials for Windows Systems, it will be logged as Credentials for Windows Systems: Inherited in the History tab of the device.
Various other minor fixes and improvements, updated user manual.
We updated the Spanish language files for certain selected sensor types.
We changed Bytes (File) to Bytes (Disk) in the Channel Unit Configuration of the VMware Datastore (SOAP) sensor to better match the size of datastores. Please note that this change will come into effect only when you add this sensor type as new and does not affect any existing sensors.
We fixed an issue for the HTTP transaction sensor that could not access a target URL anymore in certain cases and reported the error message String not found in the previous PRTG version, or when you changed to Compatibility engine in the sensor settings the error message was Object reference not set to an instance of an object.
We fixed an issue that could cause a higher memory consumption especially on the Multi-Platform Probe when you ran MQTT sensors and OPC UA sensors on your system. We therefore also updated our MQTT library to version 1.3.13 what patches several issues.
Your Microsoft Azure SQL Database sensor will now report an according sensor message when the monitored single database or elastic pool is in a different state then Online or Ready. Previously, the sensor reported an error message The queried field "average,count,maximum,minimum,total" is empty. when, for example, the queried database was in status Paused.
The QoS (Quality of Service) One Way sensor now no longer displays any IP address in the Quality of Service Measurement section for Target Probe when you are about to create this sensor type. Previously, the sensor displayed 127.0.0.1 for the local probe what did not reflect the actual probe ID being used.
We fixed an issue where in certain cases the message reported by the sensor suddenly displayed only OK after some time. In these cases the message of the sensor was reverted from the original to OK when the message sent from Probe to Core contained an empty string for some reason. The issue occurred for sensor types like WMI Custom String sensor, SNMP Custom String sensor and REST Custom v2 sensor.
We fixed an issue that occurred for certain sensor types, like the SNMP Custom v2 sensor, where an additional text overlapping the help box was displayed in the section for Schedules, Dependencies and Maintenance Window. Additionally the default dates for Maintenance Begins and Maintenance Ends were not displayed correctly.
We fixed an issue for the SNMP HPE ProLiant Physical Disk Sensor that reported an error Disk: Required field, not defined when you added multiple disks where at least one disk was defective, e.g. did not report serial number and model values. As a result, the sensor could not be created and additionally the PRTG configuration file could also no longer be saved. You will now be able to save your PRTG configuration file again even if your SNMP HPE ProLiant Physical Disk sensor includes a defective disk.
We fixed an issue for the Windows Print Queue sensor that did not report the correct sensor message when monitored printers were offline or paused. The sensor wrongly reported the status message up in these cases.
We fixed an issue where in certain cases API calls to PRTG failed with the error Unauthorized although the API token was valid. For example, when you use the API endpoint /api/table.json to reach PRTG with a valid created API key, it could happen that the call resulted in an Unauthorized message.
We fixed an issue for sms notifications that were cut off in the text when you used certain special characters, like for example ampersand &.
You can now use Probe Transfer and Configuration Viewer in the PRTG App for Desktop when you have configured a proxy server under Probe Connection Settings in your PRTG installation. In the previous PRTG versions, the remote probe would not connect to the server if you enabled the Probe Transfer feature and if you had a proxy server configured on your PRTG installation. The beta feature Template Transfer for custom device templates from one PRTG server to another will now work as well with a configured proxy server.
We fixed an issue for Paessler PRTG Hosted Monitor where you could not change the Inherit From option for Access Rights when you right clicked on a probe in order to edit access rights from the menu. Instead of the Inherit From option you would see the message You need full access rights to view or edit access rights for this object. although you were logged in with a user that has administrative rights.
We fixed an issue for the Find Duplicates feature on /api/findduplicates.htm. Previously, if you selected the option Find Duplicates from the device Context menu the result you would have received was empty.
With this version we discontinue the below already deprecated sensors:
If you run any of these sensor types they will show an error message This sensor type was removed from PRTG. For more information, see https://kb.paessler.com/en/topic/68227. (code:PE258), when you update your PRTG installations to version 24.1.94. You can pause existing sensors afterwards but you will not be able to deploy them anymore.
For further information about sensor deprecation and discontinuation in general as well as successor sensors and sensor alternatives please see our Knowledge Base articles: What do deprecation and discontinuation in the context of sensors mean? and What sensors are deprecated and what are their successors or alternatives?
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.1.93.1655
You will now need to configure the probe adapter connection to the NATS server through the PRTG web interface. You can set up your probe adapter configuration in the Core & Probes tab of the System Administration in the Multi-Platform Probe Connection Settings section. In this section you can choose the Multi-Platform Probe Connections, add a NATS Server URL, NATS Server Name, NATS Password, choose the NATS Server Certificate Authority Handling and finally choose the Connection Log Level where you can define the log severity level to determine which logs appear in the probe adapter log file. For this field you can choose one of the options offered from a dropdown menu: Error, Warning, Info (default), Debug, Trace.
We fixed an issue for the PRTG application server that ran into panic mode when you ran a mini probe on your PRTG installation, for example a Python Mini Probe or a PRTG Mobile Probe for Android. The created panic log would display the error panic: runtime error: invalid memory address or nil pointer dereference in these cases.
You can now configure and manage your Credentials for Windows Systems in the device settings in the new UI and also via API v2. This enables you to use sensors on your device which require windows authentication, like WMI sensors. The available fields are Domain or Computer Name, User Name and Password. You can also see and manage the Inherit From toggle and enable or disable it. The windows credentials will also be visible in the new UI when you set them via APIv2 PATCH request on the endpoint /api/v2/devices/{id}. Additionally you are now able to edit the following device settings in the new UI and APIv2: Credentials for VMware/XenServer, Credentials for AWS, Credentials for Script Sensors, Advanced Network Analysis.
We improved the navigation in the mobile view for the new UI. When you click on the menu icon it opens a drawer from the left hand side. The drawer remains open during navigation and you can close it with the x button. Additionally, when you select home in the side bar, you will see links to the sections Welcome and Quickstart.
We updated the German and Spanish languages files.
We fixed an issue where the messages for the Syslog Receiver sensor and the SNMP Trap Receiver sensor were not displayed in the Messages and Sensor Overview tab after updating to the previous PRTG Preview version 24.1.92.1496.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.1.92.1545
The Cisco Meraki License sensor monitors Meraki licenses of an organization and the Cisco Meraki Network Health sensor monitors the health of Cisco Meraki network devices. Both sensor types use the Cisco Meraki Dashboard API. We released these sensor types as experimental sensors with PRTG version 22.1.74.1869.
This sensor monitors VPN connections of your Fortinet FortiGate firewall. The sensor shows the number of connected SSL clients, as well as the number of both up and down IPsec tunnels. We released this sensor type as experimental sensor with PRTG version 22.1.74.1869.
This sensor allows you to send a HTTP request (HEAD, GET or POST) and use placeholders, similar to the REST Custom v2 sensor. We released this sensor type as experimental sensor with PRTG version 22.4.81.1532.
The Local Folder sensor monitors a local folder on a probe system. We released this sensor type as experimental sensor with PRTG version 21.3.70.1629.
The Network Share sensor monitor a Server Message Block (SMB) or Common Internet File System (CIFS) network share. We released this sensor type as experimental sensor with PRTG version 21.4.73.1656.
The Ping v2 sensor comes with a new setting Inverted Error Status different to its predecessor. If you select Enable for this new setting, the sensor shows a Down status if the target device is reachable. The Ping v2 sensor supports IPv6. We released this sensor type as experimental sensor with PRTG version 22.4.81.1532.
This sensor monitors the virtual disks of your Redfish capable servers and shows capacity and status. We introduced this sensor type as experimental sensor with PRTG version 21.3.71.1416.
This sensor type comes with the same basic settings as the already existing SNMP System Uptime sensor including the additional Data Source setting under the section SNMP Uptime Specific, where you can select the object identifier (OID) the sensor gets its uptime from. The Data source is also depicted in the sensor status. We released this sensor type as experimental sensor with PRTG version 23.2.84.1566.
This sensor monitors the status of processes within an Orchestra scenario. Please note that this sensor requires a Soffico license and as of Orchestra 4.8.2.5. We released this sensor type as experimental sensor with PRTG version 23.4.90.1299.
The Multi-Platform Probe enables you to deploy probes on platforms not supported by the Remote Probe, including various Linux distributions and ARM hardware.
In this latest release, we provide TLS support, ensuring a secure and encrypted connection to the NATS server. Additionally, we've included a user-friendly setup wizard for the NATS server, streamlining the installation and configuration process.
For more information about the Multi-Platform Probe please see our Knowledge Base article: What is the Multi-Platform Probe and how can I use it?
For detailed release notes please see our Knowledge Base article: What are the release notes for the Multi-Platform Probe?
We improved the creation of API keys via API call requests to match the given access rights. Previously, it was possible to create an API key for a read/write user with the parameter accesslevel_new=full via GET request, although the user only has write access at the most according to the API key access rights settings. The Access Level for the created API key then wrongly displayed full access.
We fixed an issue where an authenticated attacker could craft a specific request against the editlicense.htm endpoint and change the license of PRTG partially affecting the availability of PRTG. The severity is 4.3-Medium and calculated as CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L.
Various other minor fixes and improvements, updated user manual.
We fixed an issue for historic data reports that displayed not all or additional hours in the Date Time table when the user has set a different time zone under My Account in the PRTG Web Interface. For example, when your time zone in your account was set to (UTC -6:00) and you ran a historic data report for 12 hours, the report would in this case substract the hours in the Date Time table from the UTC time zone set under your account.
We fixed an issue where in certain cases the Core.log reported the following errors failed loading MQTT transport library: The specified module could not be found or failed loading OPC transport library: The specified module could not be found. Sending test OPCUA Publish notifications or MQTT test notifications also resulted in an access violation in these cases. The issue occurred in the previous Preview version 23.4.91.1566 because internal notification dependency was updated to use a higher OpenSSL version then the PRTG installer provided.
We fixed an issue for lookup files where changes were not reflected in the web interface when you changed values in lookup files after OID library creation. Changes to lookup values were only displayed after a complete PRTG core server restart. The issue affected for example the SNMP Library sensor, but also other sensors that come with value lookups and appeared only for the first modification in the lookup file.
We fixed an issue for public maps where the map access failed with the error message Map refresh failed in certain cases. The issue occurred for read-only users that had Read Access to a public map in the according PRTG User Group but different security contexts, for example No Access, for objects in a public map. Public maps are now displayed for read-only users but only show the objects the read-only users have access to according to the security context.
Your AWS RDS v2 sensors now display the correct values for the channel Database Connections again. The sensors displayed a wrong amount of connections in the mentioned channel with PRTG stable version 23.4.90.1299 since the sensors pulled the metric for 'SUM' and not 'AVG' (average) for Database Connections.
We fixed an issue for certain sensors on addsensor.htm that could be added although the device or group to which you want to add these sensor types did not have corresponding credentials. When you tried to add an AWS sensor, for example, to a device without Credentials for AWS, you received an error message Sorry, the scan for available monitoring items has failed! The AWS sensors will now be displayed as inactive on addsensor.htm with a hint that valid credentials are needed when you try to add them to a device without Credentials for AWS. This issue was also fixed for the Local Folder sensor (BETA) and the Network Share sensor (BETA).
We fixed an issue that occurred when you renamed a device or group via context menu in the device tree that contained Credentials for Microsoft 365. The error message was The validation of the data you entered has failed and settings could not be saved when you tried to rename the device or group with right click on edit and rename. The issue also occurred when you tried to edit the access rights in the device tree in these cases.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.1.92.1496
We improved the security for the usage of Python scripts with the Script v2 sensor. All PYTHON* environment variables that might be set, like PYTHONPATH or PYTHONHOME, will be ignored when you execute scripts with the Script v2 sensor by using the parameter -E. This parameter prevents that a different e.g. PYTHONPATH is set and that Python scripts with potential security issues are run in the Python script directory.
We fixed an issue for the SNMP Uptime v2 (BETA) sensor that displayed wrong values in the Live Data section of the sensor in the System Uptime channel. The issue occurred when you added the sensor to your PRTG local probe, however, it displayed the correct values when you have added it to your Multi-Platform Probe.
We introduced a new header for PRTG in mobile view where the menu is positioned on the top left side. The parent breadcrumb will be displayed on the top right side. The main page title Home was removed.
CVE-2023-51630 - ZDI-CAN-21182: An XSS vulnerability was identified through the htmclass parameter in the error.htm in PRTG 23.4.90.1299 and earlier versions where an attacker could bypass the authentication by creating a malicious link and luring a PRTG user with an active session to click it. The severity of this vulnerability is high and received a score of 8.8, (CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).
For further information, please refer to ZDI-24-073 and CVE-2023-51630
We would like to thank n1nj4sec for working with Trend Micro Zero Day Initiative and responsibly reporting this vulnerability.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 24.1.91.1583
We fixed a reflected XSS vulnerability which allowed JavaScript injection. The severity is 6.1-Medium and calculated as CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N.
We added the option for SNMP Trap notifications to include the sensor ID that triggers the notification in the trap message. If you select the option Include sensor ID in the Send SNMP Trap notification template, PRTG will send it on the OID 1.3.6.1.4.1.32446.1.1.5. Previously, parsing the sent trap messages was not possible for certain third party systems due to the missing option.
To ensure secure communication furthermore we updated to the OpenSSL version 1.1.1w.
Various other minor fixes and improvements.
We updated the German and Spanish language files for certain selected sensor types.
You can now send support bundles with the Contact Support option when you have configured a proxy server in the PRTG Core & Probes settings.
Important: The issue still appears in the Paessler PRTG app for desktop.
You will now receive a proper error message Error (Bad Request) again when you enter an invalid (old) password under My Account in your Account Settings. In the previous PRTG version there was a log entry in the Core webserver log Error: The validation of the data you entered has failed, but no corresponding error message in the web interface. The issue occurred when you selected the option Specify a new password and entered an invalid Old password.
We fixed an issue that caused the inheritance to be disabled for all settings of a device if you changed settings in the Device List before. The issue occurred when you selected several devices in the Device List via Settings option in the multi-edit and saved the changes. The settings of the devices where you made the changes for were set to disabled in the Inherit From toggle.
We fixed an issue for an unauthorized Ajax error that occurred in certain cases in the CoreWebServer.log instead of displaying the correct error message Your user account is not allowed to access this information. The issue happened when you were logged in with a user account whose assigned user group has write permissions on a library but who is not allowed to access user information when you clicked on the Security Context link for the user to see the User Account Settings.
You can again change the background image of a Map in the Map Settings. If you changed the background image of your map and saved the changes, the map would still display the old image as the new one was saved under an incorrect map ID in the previous PRTG version.
You can now sent reports by email again for scheduled reports in the Report Schedule setting. Previously, when the report schedule sent out an email to a configured email address or PRTG user group you would receive an access violation in the Core.log and in certain cases also the message Error sending Report Email. The issue occurred if you selected a schedule for a report in the Report Schedule setting with Target Email Address and/or Email to User Group.
We fixed an issue where PRTG stored the data for the Installation Path in the same folder as for the Data Path when you selected to run the PRTG installer in the Custom mode for fresh installations since PRTG version 23.3.88. The issue happened when you changed the Data Path directory in the path field directly.
We fixed an issue where you could not save your Scanning Intervals in certain cases when you used a regular interval and a UTC interval with the same unit. For example, if you entered 4h and @UTC 4:00 at the same time in the Available Intervals section you would receive a validation error upon saving your changes.
Your remote probes that you have deleted from the device tree will no longer appear on your PRTG Status Page under the Probes and Database Objects sections, or in the information returned when you execute a query on PRTG Health System Information via an API call /api/health.json?. In the previous PRTG version, a deleted remote probe would still be displayed on the mentioned sections with the status disconnected.
We fixed an issue that caused the environment variable AWS_EC2_METADATA_DISABLED to be leaked into the environment of other sensors. For example, it did not work in cases when you had PRTG installed on an AWS environment and ran a script with a Python Script sensor that pulled credentials from an API although the role on AWS allowed PRTG to authenticate with an AWS SDK. The environmental variable was set to AWS_EC2_METADATA_DISABLED=TRUE in this case.
Your Veeam Backup Job Status Advanced Sensor is now able to display the correct value for the channel Job Scheduled when the scheduled job has been disabled. The channel Job Scheduled will now display the value No where previously the channel would have displayed the value Yes.
For more information please see our Knowledge Base article:https://kb.paessler.com/en/topic/89136 .
TWe fixed an issue where a second tooltip icon with tooltip text was displayed in the section Percentile Handling in the Historic Data Tab of a sensor. You could observe this behavior when you selected the radio button for Show Percentiles. The second tooltip would be displayed for Percentile Averaging Interval.
You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:
Preview 23.4.91.1566
The Redfish Virtual Disk sensor (BETA) is now able to handle disks that have one of the following states: Enabled, StandbySpare, InTest, Starting, Quiesced, Updating and Qualified. Previously, the sensor could handle only the state Enabled and would display the status offline for all other states.
We fixed an issue where it was possible to escalate privileges for API-Keys.