• Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
 
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
Paessler
                    - The Monitoring Experts
  • Products
    • Paessler PRTG
      Paessler PRTGMonitor your whole IT infrastructure
      • PRTG Network Monitor
      • PRTG Enterprise Monitor
      • PRTG Hosted Monitor
      • PRTG MSP Edition
      • PRTG OT Edition
      • PRTG extensionsExtensions for Paessler PRTGExtend your monitoring to a new level
    • Icon Features
      FeaturesExplore all monitoring features
      • Maps & dashboards
      • Alerts & notifications
      • Multiple user interfaces
      • Distributed monitoring
      • Customizable reporting
      • Network Topology
  • Solutions
    • By TeamFor your organization size
      • Small Business IT
      • Mid-Market IT
      • Enterprise IT
      • MSP Network Monitoring
    • Industries
      By IndustryFor your business sector
      • Industrial
      • Healthcare
      • Energy
      • Government
      • Education
      • Data Center
      • Finance
    • IT Topics
      By Use CaseFor every technical scenario
      • Network Monitoring
      • Server Monitoring
      • OT Monitoring
      • Distributed Monitoring
      • Network Topology Mapping
      • SNMP Monitoring
      • Bandwidth Monitoring
  • Pricing
  • Resources
    • Getting Started
      Getting StartedModules for self-paced learning
    • How-to Guides
      How-to GuidesGet the most out of PRTG
    • Videos & Webinars
      Videos & WebinarsLearn from Paessler experts
    • Case StudiesProven results across industries
    • PRTG ManualFull documentation
    • Knowledge Base
      Knowledge BaseShare community knowledge
    • PRTG Sensor Hub
      PRTG Sensor HubGet sensors, scripts & templates
    • Trainings
      PRTG TrainingLearn how to work with PRTG
  • Partners
    • Icon Handshake
      Become a PartnerFor resellers and channel partners
    • Icon MSP
      Become an MSPDeliver monitoring as a managed service
    • icon partner
      Partner PortalLog in to your partner account
    • Deal Registration
      Deal RegistrationRegister your sales opportunities
    • icon search
      Find a PartnerFind partners selling Paessler products
    • icon technology
      Technology AlliancesSee Paessler technology partnerships
    • Partner HubTools for Your Success
  • Company
    • About Us
    • Press Center
    • Careers
    • Blog
    • IT Knowledge
    • Contact us
  • Contact us
  • Login
  • English
    • Deutsch
    • Español
    • Français
    • Italiano
    • Português
  • Get a quote
  • Free trial
  1. Home>
  2. Paessler PRTG>
  3. Version history>
  4. Preview release notes

PRTG Release Notes:
Preview Channel

Early Access to New Features

  • Preview versions give you early access to the latest features and improvements before they reach the stable channel. These versions have been thoroughly tested in our labs, but may still contain limitations in certain monitoring configurations. We do not recommend using preview versions in production environments.
  • To update your PRTG installation with the latest preview version, use the Auto-Update feature: In the PRTG web interface, navigate to Setup | Auto Update.
  • Looking for the most reliable version for your live environment? Check out our Stable Release Notes.
Stable Channel

PRTG Preview Version 23.3.88.1319

Release date: August 30, 2023
Improved

Improved

AWS EC2 v2 and AWS RDS v2 sensorsSensors

Your AWS EC2 and AWS RDS v2 sensors will show a warning message if the limit of the channel CPU Credit Balance limit has less than 1 credit available. Previously the sensors were showing an error status. Please note that this change applies only when you add this sensor type as new sensor.

MQTT Subscribe Custom sensorSensors

We added two new options in the MQTT Specific settings of the MQTT Subscribe Custom sensor for a better message handling. The option Add duration since last message will set a threshold alarm that will notify you when no message was received. Previously, the sensor went into unknown status before when no message was received in the scan interval. This default behavior will remain if the setting for Add duration since last message is not enabled. The option Retain last sensor value keeps the last message on the live charts and allows you to monitor specific JSON values of the payload.

SNMP Buffalo TS System Health SensorSensors

Your SNMP Buffalo TS System Health sensor is now able to display an additional status for the channel Firmware Update Available. Previously, the status was not included in the lookup file and therefore displayed an error with the message undefined lookup value (3) when the value 3 was sent to the sensor. The value 3 in this case represents the status latest.

All parts of PRTGVarious

Various other minor fixes and improvements.

Sensor LanguagesVarious

We updated the Spanish and German language files for certain selected sensor types.

Fixed

Fixed

Cluster SetupServer

We fixed an issue that caused the Failover node to become unreachable when you added a new contact to the Notification Contacts settings of the Master node.

DependenciesServer

We fixed an issue where dependent objects, like sensors and devices, were not paused if the configured master sensor went into error status due to exceeded limits. When you configured the sensor under Dependency Type as Master sensor for parent then the issue occurred in rare cases when the sensor was not saved to the device tree while the limit status changed. The issue only affected newly created sensors.

LibrariesServer

You can now create libraries again when you are logged in as a user with read/write access. This did not work before in the previous PRTG version 23.3.86.1520 when you were logged in as a read/write user that has full access in the according user group. You would get an Unauthorized ajax error message for adding a new library before.

NotificationsServer
  • We fixed an issue for the notifications template Send Syslog Message where the message contained a wrong character (?) at the beginning, regardless of the format (ANSI, UTF-8) you selected before.
  • We fixed an issue in the delivery of sms notifications that occurred in cases when you used NowSMS service as an sms endpoint for PRTG. The delivery of sms notifications was delayed in these cases in the previous PRTG version.
Probe connectionServer

We fixed an issue where in certain cases the probe service stopped working and caused the probe to disconnect from the PRTG core server. The probe service then reported a high CPU usage in these cases and sometimes access violations were logged in the PRTG probe.log additionally. The issue was probably caused by the DNS v1 sensor that we declared as deprecated with PRTG version 21.3.69.1333 and which was replaced with its successor DNS v2 sensor. For more information about deprecated sensor types and their alternatives please see our Knowledge Base article: https://kb.paessler.com/en/topic/89505.

Scanning IntervalServer

We fixed an issue in the Monitoring settings for the Scanning Intervals section. You can now enter multiple scanning intervals again with the format of Coordinated Universal Time (UTC) points, like @ UTC hh:mm , hh:mm. Previously intervals with the "@ UTC" format were treated as duplicates and the entries could not be saved. Please note that you have to enter different time periods in the scanning intervals when you add multiple intervals in the UTC format.

Note:The input validation still incorrectly fails when you add a UTC at a full hour that is already set as hourly scanning interval. For example, @ UTC 06:00 fails to save when there is already a scanning interval with 6h while @ UTC 06:01 would work in this case.

Add sensorSensors

We fixed an issue for certain sensor types that ran into the error no available in the Specific settings of the sensor during sensor creation. The issue happened when a timeout value higher than 300 was set in the registry for the initial sensor scan when you added the sensor. Sensor types affected were Microsoft 365 Service Status Advanced, Veeam Backup Job Status Advanced sensor, for example.

Beckhoff IPC System Health sensorSensors

The Beckhoff IPC System Health sensor now supports IPv6 as IP Version connection that you can configure in the Basic Device Settings under IP version of the monitored device. The sensor appeared under Sensor types that are not IPv6 compatible in the previous PRTG versions due to a missing compatibility flag in the sensor library.

Custom sensor channel namesSensors

We fixed an issue for custom sensor types, like the HTTP Push Data Advanced sensor, where channels were created as duplicate when there was a trailing whitespace behind the relevant channel name. The issue occurred after a PRTG core server restart. The whitespace was removed and since it did not match the previous channel name, the sensor would create a duplicate.

HTTP sensorsSensors

We fixed the handling of HTTP methods that are returned after a redirect to follow the Post/Redirect/Get (PRG) pattern. This prevents the contents of the original POST to be resubmitted by redirecting the client to another location. If you select the Request Method POST, for example, under the HTTP Specific settings of the sensor, then the first request will use this method. If a request is redirected, all further requests will use GET. Redirects of requests that use GET and HEAD will continue to use GET and HEAD, respectively. This change affects all HTTP based sensor types, like the HTTP sensor and HTTP Advanced sensor.

Microsoft AzureSensors

Your Microsoft Azure sensors now query data in a slightly longer time span to make sure data is returned from Microsoft Azure and that every time stamp is considered. Previously, it could happen that Azure did not return any value when the queried time span was too close to the present as it would query only the most recent one and not also the latest data.

Note: The Microsoft Azure SQL Database sensor will throw an exception in case no result is returned from timeseries. Microsoft Azure Storage Account and Microsoft Azure Virtual Machine sensors return default value = 0 in case no result is returned from timeseries.

NetApp I/O v2 sensorSensors

We fixed an issue for the NetApp I/O v2 sensor that occurred with the ONTAP version update to 9.12.1P3. Due to changes in the API, the sensor received additional unexpected information which resulted in an error with the message The queried field "value" is empty for NetApp Cluster systems.

OPC UA sensorsSensors

We fixed an issue for OPC UA sensors that could run into a memory leak on the probe system causing the probe service to stop. The issue occurred only in certain cases when you ran a large number of OPC UA sensors, like OPC UA Certificate sensor, OPC UA custom sensor and OPC UA Server Status sensor with a short scan interval.

Redfish System Health sensorSensors

We fixed an issue for the Redfish System Health sensor that in certain cases reported an error when the monitored device did not sent a Thermal service. The sensor ran into an exception and reported the error message No 'Thermal' service found in Redfish chassis. The channel for Thermal Status will now report the status Offline/Absent when there is no Thermal data sent by the monitored device. The channel for Thermal Status will not be created if the target system does not support this service determined with the first scan.

SNMP Cisco System Health sensorSensors

We fixed an issue for the SNMP Cisco System Health sensor that resulted in sensor logs that were written into the \Logs\sensors folder when you have selected the option Discard result in the Debug options of the sensor. The sensor kept overwriting the log files in this case when the store result option was disabled. Additionally, the sensor disabled the option Store result automatically after writing log files and reset it to Discard result. We also fixed this behavior so that you can now edit the options again manually.

SNMP Custom String sensorSensors

We fixed an issue for the SNMP Custom String sensor where the parameter for the setting Interpret Result As was always set to the String (default) option, regardless of the option you set before. This issue occurred when the sensor was used in a device template.

SNMP Nutanix Hypervisor sensorSensors

Your SNMP Nutanix Hypervisor sensor will display the speed in the column Last Value (speed) for Bytes Received when you update to this PRTG version. In the previous PRTG versions, the Last Value (speed) for Bytes Received was missing and had the unit Megabyte instead of Mbits configured.

Cloning sensorsPRTG App for Desktop

We have fixed an issue that prevented a sensor from being cloned to more than one device. The same issue would also occur if you tried to clone another sensor to another device after the first clone attempt. In both cases you would receive an error message stating Invalid operation. You can now clone a sensor (or different sensors) to more than one device.

CommentsPRTG App for Desktop

We fixed an issue that prevented you from saving new or edit existing comments in the Comment tab of a device or a sensor.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 23.3.88.1319

  • sha256_exe 0DE28D5BAEDA03DDAF79C7D372EF6D60BE19F516D1891AB8BA53B98ADA98EC8A
  • sha256_zip 7837E02A061917910E5140F285A41985FAABA376AA91BD52CD890CBEE015D3F8
Lab

Lab

HTTP v2Sensors

We improved the handling of HTTP requests for the HTTP v2 (BETA) sensor to follow the Post/Redirect/Get (PRG) pattern.

REST Custom v2 sensorSensors

We fixed an issue for the channel setting Custom Unit in the REST Custom v2 sensor that was displayed even if you selected a different unit than custom. The field will now be displayed only when you have selected Custom (default) for the relevant channel as unit before.

PRTG application serverPRTG API v2
  • We fixed an issue where the PRTG application server went down in certain cases with the previous PRTG preview version 23.3.87.1579. The error was reflected in the Application Server Health (Autonomous) sensor that showed a down status. The workaround was to restart the PRTG core server to make the PRTG application server run again.
  • We fixed an issue for the PRTG application server that ran into panic mode during startup process in certain cases.
Device TreeNew UI

We fixed an issue that resulted in a missing cloned group in the new UI tree when you have cloned the group before in the classic UI and removed one device from the cloned group afterwards. Instead of only missing the deleted device in the new UI the whole group was gone in these cases.

Web InterfaceNew UI

We improved the navigation behavior of cards on the device and sensor overview pages.

PRTG Preview Version 23.3.87.1579

Release date: August 8, 2023
Improved

Improved

SecurityServer

Your API Keys are no longer logged in a readable format in the CoreWebServer.log when you have created an API key and executed an API call request with it. The issue only occurred for the Log in Debug Level.

Microsoft 365 Mailbox sensorSensors

You can now filter emails that match a defined regular expression. The new filter filters email whose Subject, From or Body fields match the defined regular expression. You can set the new option under the Microsoft 365 Settings.

Important: The regular expressions filter will result in the Down status if there are more than 10,000 emails in the mailbox folder you want to monitor. This is because the regular expression filter is applied after the emails are retrieved from the API. The larger the volume of emails, the greater the impact on performance. Enable the Filter by Age setting or use a non-regular expression filter in addition to the regular expression filter to reduce the number of emails.

All parts of PRTGVarious

Various other minor fixes and improvements.

Sensor LanguagesVarious

We updated the Dutch language files for certain selected sensor types.

Fixed

Fixed

NotificationsServer

We fixed an issue that prevented notification templates from being edited within the notification trigger tab.

PRTG Administration ToolServer

You can now enter a folder path with a folder that contains ANSI-characters, like umlauts or accents, in the PRTG Core Server Tab of the PRTG Administration Tool. Please note that this change does not work for unicode characters, like the Cyrillic language. If you select a folder path that contains non-ANSI characters or if you enter a folder path name with such in the field for Local Storage of Data Files and Monitoring Database, then an according error message will be displayed.

PRTG InstallerServer

During PRTG installation, when the license server is unreachable due to connection or license expiration issues, the following error message will be displayed: Either the license server is not available because you are offline, or you cannot use the current version of installer because your license has expired. Please check your connection or log into the Paessler shop, make sure your maintenance contract is active and restart the installer. Previously, the installation displayed an error with the message that the license is invalid or that maintenance has expired.

Single Sign-onServer

We fixed an issue where in rare cases the execution of the button Test Single Sign-On Authorization Endpoint led to an access violation. This issue occurred only in very rare cases if your Application (Client) ID for loading the configuration contained a blank space at the end.

User groupsServer

We fixed an issue for user groups that had the setting Allow user group members to create certain sensors only enabled. When you created a user group with the mentioned setting and did not select any sensor types in the list, then all the sensor types would be selected after a PRTG core server restart for this user group.

HL7 sensorSensors

We fixed an issue for the HL7 sensor in the settings for Message Header where the Default message header was overwritten in certain cases. The issue happened when you entered data for the setting Override message header but you activated the radio button for Default message header afterwards. In those cases, the sensor always took the override parameters instead of the selected default headers from the script.

HTTP Push DataSensors

Your HTTP Push Data sensors will show again their values in the Last Value column of the channel list of the sensor as well as in the channel gauges of the sensor Overview tab. The Last Value column did not display any data before in the previous PRTG versions for the HTTP Push Data sensor, HTTP Push Data Advanced sensor and HTTP IoT Push Data Advanced sensor.

SNMP sensorsSensors

Your SNMP Disk Free and SNMP Memory sensors now display valid values for monitored disks with a larger size >16 terabyte and memory storage >2 terabyte again. In the previous PRTG versions, these sensor types displayed random values or reported an error code 2003.

SSL sensorsSensors

We fixed an issue for the SSL Security Check sensor and SSL Certificate sensor that did not work anymore when a SOCKS proxy server for sensor connection was used in the previous PRTG versions. The sensors reported an error with the message The connection has dropped (PE039) in these cases.

Probe TransferPRTG App for Desktop

We fixed an issue where the transfer of your probes to another server may have failed in certain cases and resulted in a deadlock with the previous PRTG versions. With PRTG version 23.2.84.1566 we announced that you can find the Probe Transfer feature for PRTG Desktop under Probe Connection Settings in the PRTG setup and that it is no longer available in the Experimental Features section.

Note

Note

PRTG application serverKnown Issues

The application server may be down in certain cases when you update to this PRTG preview version 23.3.87.1579. You can see this with the Application Server Health (Autonomous) sensor that shows a down status. As a workaround, please restart your PRTG core server to make the application server go up again. We will deliver a fix for this issue in the upcoming PRTG versions.

Solved with Preview PRTG 23.3.88.1319

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 23.3.87.1579

  • sha256_exe F546C7101EA149000F6A77CEC655D594E7CD56ECAC582044E26E0DE13FF254D9
  • sha256_zip 4CCAA810221223DF00755CCDC4030EB468C6CB7E586AA109C40116BDBC308F33
Lab

Lab

Device settingsPRTG API v2

We fixed an issue where it was not possible to pause a device via API with /api/v2/devices/40/pause.

API KeysPRTG API v2

You can now create, read, update and delete API-Keys with HTTP requests via PRTG API v2. For example, a POST request to users/{id}/api-key will create an API key with name, description and access level properties for the user. For more information about how to use HTTP requests in the PRTG API v2 concerning API keys please see our updated Knowledge Base article: https://kb.paessler.com/en/topic/90008.

Device SettingsNew UI
  • After searching for a value in the Filter Setting Sections the relevant to your search device setting sections remain expanded even after changing the respective search text value in your device settings.
  • Collapsed Device Setting sections that contain invalid fields will expand when saving your changes.
  • Setting sections that contain validation errors are no longer hidden when applying a filter to the device settings.
REST Custom v2Sensors

We improved the handling for JSON-path expressions in the REST Custom v2 sensor that in some cases could not be mapped if there were boolean strings with true and false. The mapping now works for counter and integer Value Type in the Channel Settings of the sensor with a given JSONPath/XPath.

SNMP Traffic v2Sensors

You can try out the experimental SNMP Traffic v2 sensor. The SNMP Traffic v2 sensor monitors bandwidth and traffic on a device via the Simple Network Management Protocol (SNMP). This sensor type has the same basic settings as its predecessor and comes with the additional channels Broadcasts In (number of incoming broadcast packets), Broadcasts Out (number of outgoing broadcast packets), Multicasts In (number of incoming multicast packets), and Multicasts Out (number of outgoing multicast packets). This sensor is not affected by the following SNMP compatibility options set in the parent device: Port Name Template, Port Name Update, Port Identification, Start Interface Index, and End Interface Index.

PRTG Preview Version 23.3.86.1515

Release date: July 12, 2023
Improved

Improved

LanguagesVarious

We updated the German and Spanish language files.

Fixed

Fixed

PRTG installerServer

We fixed an issue for the PRTG installer when you selected to run it in the Custom installation mode. The issue occurred in the previous Preview version 23.2.86.1462 for fresh PRTG installations and when you used the default data path C:\ProgramData\Paessler\PRTG Network Monitor here. In this case you could not proceed on to the next installation step and the PRTG installer reported an error message The Setup program cannot access the selected data path. Check your Windows access rights or select a different directory.

User accountsServer

We fixed an issue that resulted in an automatically created new user group when you have added a new user account in the previous Preview version 23.2.86.1462. This user group was also wrongly assigned as Primary Group to the user.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 23.3.86.1515

  • sha256_exe EAF4365079532BF00E0FEF602F60E6E956A1D58128A6AB09FB5D1EB0E1437C26
  • sha256_zip F32CCFE19DC31A8D77DF026223C5763FDBBBE021866C71BA8FBCA8C998D453F6

PRTG Preview Version 23.2.86.1462

Release date: July 4, 2023
Improved

Improved

VulnerabilitiesSecurity
  • We fixed a vulnerability where a PRTG user with write permissions could trick a few sensors into creating possibly executable files on the host system, which could then be executed under certain circumstances.
  • We fixed a vulnerability where it was possible to bypass the CSRF protection.
  • We fixed a vulnerability where it was possible for a PRTG user with write permissions to trick certain sensors to use sensor specific files from unintended locations on the host system which could lead to arbitrary actions within the capabilities of the sensors.
  • We fixed a vulnerability where a target url could be tricked to redirect the user to foreign domains.
Sensor SecuritySensors

We fixed a vulnerability that could enable an authenticated and authorized malicious user to write an arbitrary file on the probe system. The issue affected the exe sensors FTP Server File Count sensor and HTTP XML/REST Value sensor. The vulnerabilities can be tracked under CVE-2023-22631 and CVE-2023-22632.

For further information please also see our Knowledge Base article: https://kb.paessler.com/en/topic/91756

All parts of PRTGVarious

Various other minor fixes and improvements.

Fixed

Fixed

PRTG installerServer

The PRTG installer now validates the access to the selected Installation Path and Data Path on PRTG installation in the Custom mode and resets the path to its default when it is not accessible. Previously, the installation displayed a fatal error with the message PRTG Webserver could not be started properly when the installer failed to write into the path due to access restrictions.

NotificationsServer

We fixed an issue for the HTTP notification type when it contained reserved special characters, such as hash symbols (#), in the placeholders of the URL which you can add in the Execute HTTP Action section. The URL string was cut off after the hash symbol in these cases.

Object namingServer

We fixed an issue on group, sensor, device and notifications level that led to several issues in the web interface when you entered an URL as name of the relevant object.

HL7 sensorSensors

We fixed an issue for the HL7 sensor that went into error status with the message Error caused by lookup value 'No' in channel 'Message Control ID OK' (AE:102 Data type error) after running for a certain period of time. The issue was located in the current date and time of the timestamp.

HPE 3PARSensors

We fixed an issue that happened within the parsing of the output for the commands executed by the HPE 3PAR drive enclosure sensor. The sensor then reported the error message Invalid response structure encountered, some data is missing for HPE Primera systems in certain cases.

HTTP AdvancedSensors

Your HTTP Advanced sensors now can use custom headers again when you have defined them in the setting for Use Custom HTTP Headers of the sensor settings. Previously, the custom headers were ignored and overwritten with a default value. We therefore also fixed an issue with the default HTTP headers where the wrong response format, e.g. XML instead of JSON, was returned in certain cases.

NetApp SnapMirror v2Sensors

Your NetApp SnapMirror v2 sensor is now able to display a correct status for the channel Transfer Status when the reverse lookup value is insync for Snapmirror continuous protections. Previously, the sensor reported an error with the message The following reverse lookup value is invalid: insync. in this case.

NetFlowSensors

We fixed an issue for the NetFlow v5 sensor where the values for Inbound and Outbound Interface were set to 16 bit instead of 32 bit in certain cases.

OPC UA SensorsSensors
  • We fixed an issue for the OPC UA Certificate Sensor, OPC UA Custom Sensor and OPC UA Server Status Sensor that went into an error status after one or more scan intervals with the message BadSessionInvalid. The issue happened during session establishment where the session timeout response from the server was not taken into account by the sensor.
  • You can now set the connection configuration for OPC UA to SecurityMode = None in the Endpoints tab with additional user name authentication via Username & Password for a user account. This combination did not work previously and the connection to the OPC UA sensors could not be established before.
Windows MSMQ Queue Length sensorSensors

Your Windows MSMQ Queue Length sensors will now run again when you update to this PRTG version. These sensor types did not work anymore with PRTG version 23.1.82.2175 and reported an error with the message Queuename not found on specified machine in certain cases. The issue occurred on remote systems with a MSMQ service running that could not be queried.

Note

Note

LibrariesKnown Issues

You currently cannot add a library with a user account that has read/write access when you update to this PRTG Preview version. When you are logged in as a read/write user that has full access in the according user group you will get an Unauthorized ajax error message for adding a new library. As a workaround, please use an admin user account instead. We will deliver a fix for this issue in the upcoming PRTG versions.

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 23.2.86.1462

  • sha256_exe 909475EFCFA182D71D7166DB6D9C6DB76E92D0C2E751CF2701A6B353F9AD283C
  • sha256_zip 5E30416A1EF2271382EAD1FD8D1210DF7C89779CF1B189C1867687A92C82E890
Lab

Lab

Cisco MerakiSensors

We fixed an issue for the Cisco Meraki License Sensor and Cisco Meraki Network Health Sensor that went into an error status when PRTG was updated to version 23.2.84.1566 with the message The sensor could not get a response from the server. 0 (). schannel: next InitializeSecurityContext failed: SEC_E_ILLEGAL_MESSAGE (0x80090326) - This error usually occurs when a fatal SSL/TLS alert is received (e.g. handshake failed).

HTTP v2Sensors

To make it more clear, we have renamed the setting from Timeout (sec.) to Timeout per Request (sec.) in the HTTP Specific settings of the sensor.

SNMP Uptime v2Sensors

We fixed an issue for the SNMP Uptime v2 sensor that reported the following error in certain cases: Could not resolve OID for 'iso.org.dod.internet.mgmt.mib-2.host.hrSystem.hrSystemUptime.0'. Either the required MIB file was not found or the name is invalid. The issue occurred only when you have added the sensor to a remote probe.

Script v2Sensors

We fixed an issue for the Script v2 sensor where the path to the Script folder was broken. The issue was fixed for the path on Microsoft Windows operating systems.

Web InterfaceNew UI
  • We fixed an issue that led to an unknown error when you logged in to PRTG after a logout and when you navigated to Monitoring view via side menu.
  • We fixed an issue that resulted in an error message "An unknown error occurred". The error occurred when you expanded the Graphs card of a sensor and then closed it with the x button.
  • You can now add channel graphs again via the Add button in the expanded view of the Graphs page of a sensor.
  • We activated the Change Password button, which previously prevented you from submitting your request to set a new password.
  • You will now see a banner when you activate the new UI that will inform you about the development status. The text message with linked Knowledge Base article is The new interface is still in development and not yet feature complete. Please take a look at our Knowledge Base to see what is coming next.

PRTG Preview Version 23.2.85.1327

Release date: June 15, 2023
Fixed

Fixed

Access KeysServer

We fixed an issue for Probe and PRTG application server access keys that were encrypted with Preview version 23.2.85.1310 what led to a corrupted PRTG configuration file in certain cases. The issue occurred only when you had more than one access keys and only when you executed a second core server restart after the update to Preview version 23.2.85.1310.

Note

Note

SecurityInstaller

You can verify the authenticity of the PRTG installer with the Secure Hash Algorithms for the following versions and release channels:

Preview 23.2.85.1327

  • sha256_exe 96A458D4C378E0488E840D6B4FB0884D015DC265CA991799953D17052BB3BA03
  • sha256_zip EDF16848F86608C1E3A52C211B753DF2629463D5F509BF209889C44D5B8B4921
1
...
11121314

Products

  • Paessler PRTG
    Paessler PRTGMonitor your whole IT infrastructure
    • PRTG Network Monitor
    • PRTG Enterprise Monitor
    • PRTG Hosted Monitor
    • PRTG extensions
      Extensions for Paessler PRTGExtend your monitoring to a new level
  • Icon Features
    FeaturesExplore all monitoring features

Monitoring with PRTG

  • Network monitoring
  • Bandwidth monitoring
  • SNMP monitoring
  • Network mapping
  • Wi-Fi monitoring
  • Server monitoring
  • Network traffic analyzer
  • NetFlow monitoring
  • Syslog server

Useful Links

  • PRTG Manual
  • Knowledge Base
  • Customer Success Stories
  • About Paessler
  • Subscribe to newsletter
  • PRTG Support
  • PRTG Consulting
  • PRTG Feedback & Roadmap

Contact

Paessler GmbH
Thurn-und-Taxis-Str. 14, 
90411 Nuremberg 
Germany

info@paessler.com

+49 911 93775-0

  • Contact us
©2026 Paessler GmbHTerms & ConditionsPrivacy PolicyImprintTrust CenterDownload & InstallSitemap
Home Home Home